| | Models | XT7-6 | XT15-4 | XT20-3 | XT30-2 | XT60-1 | XT120-0.5 | XT250-0.25 | | Output Ratings | Output Voltage Output Current Output Power | 0-7 V 0-6 A 42 W | 0-15 V 0-4 A 60 W | 0-20 V 0-3 A 60 W | 0-30 V 0-2 A 60 W | 0-60 V 0-1 A 60 W | 0-120 V 0-0.5 A 60 W | 0-250 V 0-0.25 A 62.5 W | | Line Regulation (1) | Voltage (0.01% of Vmax+2 mV Current (0.01% of Imax+0.25 mA) | 2.7 mV 0.85 mA | 3.5 mV 0.65 mA | 4 mV 0.55 mA | 5 mV 0.45 mA | 8 mV 0.35 m | 14 mV 0.3 mA | 27 mV 0.275 mA | | Load Regulation (2) | Voltage (0.01% of Vmax+2 mV) Current (0.01% of Imax+0.25 mA) | 2.7 mV 0.85 mA | 3.5 mV 0.65 mA | 4 mV 0.55 mA | 5 mV 0.45 mA | 8 mV 0.35 mA | 14 mV 0.3 mA | 27 mV 0.275 mA | | Meter Accuracy | Voltage (1% of Vmax+1 count) Current (1% of Imax+1 count) | 0.08 V 0.07 A | 0.25 V 0.05 A | 0.3 V 0.04 A | 0.4 V 0.03 A | 0.7 V 0.02 A | 2.2 V 0.006 A | 3.5 V 0.004 A | | Output Noise & Ripple (Vmode) (20 Hz-20 MHz) | RMS: Peak-to-Peak: | 1 mV 2 mA | 1 mV 2 mA | 1 mV 2 mA | 1 mV 2 mA | 1 mV 2 mA | 1 mV 2 mA | 1 mV 2 mA | | Stability (3) | Voltage (0.02% of Vmax) Current (0.03% of Imax) | 1.4 mV 1.8 mA | 3 mV 1.2 mA | 4 mV 0.9 mA | 6 mV 0.6 mA | 12 mV 0.3 mA | 24 mV 0.15 mA | 50 mV 0.075 mA | | Temperature Coefficient (4) | Voltage (0.015% of Vmax/°C) Current (0.02% of Imax/°C) | 1.05 mV 1.2 mA | 2.25 mV 0.8 mA | 3 mV 0.6 mA | 4.5 mV 0.4 mA | 9 mV 0.2 mA | 18 mV 0.1 mA | 37 mV 0.05 mA | Specifications are warranted over a temperature range of 0-30°C with default local sensing. Above 30°C, derate output lineraly to zero at 70C. (1) For input voltage variation over the AC input voltage range, with constant rated load. (2) For 0-100% load variation, with constant nominal line voltage (3) Maximum drift over 8 hours with constant line, load and temperature, after 30 minute warmup. (4) Change in output per C change in ambient temperature, with constant line and load. | Operating Ambient Temperature: 0-30°C with default local sensing. Above 30°C, derate output linearly to zero at 7°C Storage Temperature Range: -55°C to +85°C Humidity Range: 0 to 80% RH Non-condensing. Front Panel Control: 10-turn voltage and one-turn current potentiometers (10-turn current control optional) Front Panel Voltage Control Resolution: 0.02% of V max Voltage Mode Transient Response Time: <100 µs for output voltage to recover within 0.05% of previous level after step change in load current of up to 50% of rated output in the range of 25% to 100% or rated output. AC Input: 104-127 Vac at 1.2 A rms, 57-63 Hz. Maximum Voltage Difference from output to safety ground: 400 Vdc. Agency Approvals: CSA, CE Specifications with optional RS-232/GPIB Interface: GPIB - Internal GPIB Interface: Full feature GPIB programming with 14-bit resolution and software calibration. RS232 - Internal RS-232 Interface: Serial instrument programming using the RS-232 protocol. | Models | XT7-6 | XT15-6 | XT20-3 | XT30-2 | XT60-1 | XT120-0.5 | XT250-0.25 | | Program Resolution | Voltage Current OVP | 1.1 mV 1.0 mA 1 mV | 2.4 mV 0.6 mA 2.4 mV | 3.1 mV 0.5 mA 3.1 mV | 4.7 mV 0.3 mA 4.7 mV | 9.3 mV 0.2 mA 9.3 mV | 17 mV 0.1 mA 17 mV | 39 mV 0.05 mA 39 mV | | Program Accuracy | Voltage . Current . OVP | 10 mV ±0.1% 110 mA ±0.15% 70 mV | 20 mV ±0.1% 70 mA ±0.15% 150 mV | 20 mV ±0.15% 50 mA ±0.15% 200 mV | 30 mV ±0.15% 40 mA ±0.15% 300 mV | 200 mV ±0.15% 260 mA ±0.15% 600 mV | 400 mV ±0.15% 130 mA ±0.15% 1.2 V | 800 mV ±0.15% 7 mA ±0.15% 2.4 V | | Readback Resolution | Voltage Current | 1.1 mV 1.0 mA | 2.4 mV 0.6 mA | 3.1 mV 0.5 mA | 4.7 mV 0.3 mA | 9.3 mV 0.2 mA | 17 mV 0.1 mA | 36 mV 0.05 mA | | Readback Accuracy | Voltage . Current . | 10 mV ±0.15% 110 mA ±0.15% | 10 mV ±0.1% 70 mA ±0.15% | 10 mV ±0.1% 50 mA ±0.15% | 15 mV ±0.1% 40 mA ±0.15% | 35 mV ±0.15% 26 mA ±0.2% | 70 mV ±0.3% 13 mA ±0.2% | 150 mV ±0.3% 7 mA ±0.2% | Specifications with optional APG Analog Programming Interface APG - Internal Analog Programming Interface: Includes overvoltage protection (OVP), remote ON/OFF, master slave tracking. Remote Programming: 0-10 V or 0-10 kilohms = 0 to 100% of output voltage & current Remote ON/OFF: TTL compatible, selectable logic high or low Overvoltage Protection: Adjustable 3 V to Vmax +10% Master/Slave Tracking: Within 1% Output Fail Flag: Logic Low = Active |