Xantrex XPD Series DC Power Supply - Specification

  • Five models

  • Extra High Power Density
  • Smallest 500 watt DC power supply availablet
  • Power Factor Correction (PFC)
  • Zero voltage "soft" switching for low noise, high efficiency and high reliability
  • Analogue programming standard
  • Optional internal 16-bit GPIB (IEEE-488) and RS-232 control
  • Lab View® and LabWindows® drivers
  • OVP, current limit, thermal protection
  • Front and rear connectors standard
  • Ten turn voltage and current setting
  • Remote sense, 5V line loss compensation
  • CE, CSA, UL approvals

Models

XPD 7.5-67

XPD 18-30 XPD 33-16 XPD 60-9 XPD 120-4.5

Output Voltage
Output Current
Output Power

0-7.5 V
0-67 A
502.5 W

0-18 V
0-30 A
540 W

0-33 V
0-16 A
528 W

0-60 V
0-9 A
540 W

0-120 V
0-4.5 A
540 W

Output Noise Voltage (p-p, 20 MHz bw)

50 mV

50 mV

75 mV

75 mV

150 mV

Output Ripple (rms, 100 kHz bw))
Voltage
Current


5 mV
250 mA


5 mV
250 mA


7.5 mV
150 mA


10 mV
150 mA


20 mV
75 mA

Common
Load Regulation Voltage (0.01% of Vmax + 2 mV), Current (0.01% of Imax + 1 mA)
Line Regulation Voltage (0.01% of Vmax + 2 mV), Current (0.01% of Imax + 1 mA)
Meter Accuracy Voltage (1% of Vmax + 1 count), Current (1% of Imax + 1 count)
Drift (60 minutes) Voltage (0.05% of Vmax) ,Current (0.3% of Imax)
Drift (8 hours) Voltage (0.03% of Vmax), Current (0.05% of Imax)
Temperature Coefficient Voltage (0.015% of Vmax/ºC, Current (0.02% of Imax/ºC
OVP Adjustment Range Minimum (5% of Vmax), Maximum (110% of Vmax)
Efficiency >80%
Dynamic Performance
Rise Time (No load, full load) 50 ms
Fall Time (Full load) 50 ms
Fall Time (No load) 400 ms
Voltage Mode Transient Response 1 ms
Time delay from power on until output stable 3 s maximum
Input Conditions
Rated AC Input Voltage 100 / 120 / 200 / 230 / 240 VAC, universal input
Maximum AC Input Power 650 W
Operational AC Input Voltage Range 85 to 264 VAC; power factor corrected.
Maximum Input Current 7 A maximum at 100 VAC, 6 A maximum at 120 VAC, 3 A maximum at 220 VAC.
Input Frequency Range 47 to 63 Hz
Power Factor 0.98 minimum for full load at nominal voltage
Input Harmonic Distortion Currenr harmonics meet IEC 1000-3-2

Additional Characteristics

Over Temperature Protection (OTP) Sensor locations on PFC, DC-DC and ouptut rectifier heatsinks. Unit latches off when T>rated maximum.
Over Voltage Protection (OVP)

Control Adjustable on front panel single turn control. 110% setting, 5% of rated output.

Switching Frequency 100 kHz
Output Hold-up Time 10 ms @ 120 VAC input.
Maximum Voltage Differential from either output to safety ground ±300 VDC
Insulation Resistance Input to chassis: >30 Megohms, with 500 VDC
Output to chassis: >20 Megohms, with 1000 VDC
Isolation Voltage Input to output: 1350 Vac

Remote Programming and Monitoring

Remote Start/Stop and Interlock 2.5-15 V signal or TTL-compatible output, selectable logic. TTL input impedance: 2 k (in series with one diode drop).
Remote Analog Programming (Full Scale Input) Voltage and current programming inputs (source must be floating): 0-10 V (default) voltage sources. Input impedance (V and I): 20 k.
Remote Monitoring

Output voltage and current: 0-10 V
Output impedance (V and I): approximately 221 W
Output short circuit current: approximately 50 mA

Remote Programming and Monitoring Accuracy 1% of full scale output for the default range.
Maximum Remote Sense Line Drop Compensation 7.5 V model: 3 V/line
18 to 120 V models: 5 V/line.
Optional Digital Control RS-232, GPIB interfaces
Environmental
Operating Temperature Range 0 to 50°C
Storage Temperature Range –40 to 85°C
Humidity Range 0 to 95% RH non-condensing
Operating Altitude Derate maximum operating temperature by 1°C per 1,000 feet (300 m) for operation between 5,000 feet (1500 m) and 15,000 feet (4500 m).
Storage Altitude Up to 50,000 feet (15 000 m)
Installation Category Intended for use in installation category (overvoltage category) II (IEC 1010-1 standard).
Pollution Degree Category 2 (IEC 1010-1 standard).
Vibration 0.3 mm peak displacement, 0.6mm peak to peak; 10 to 55 Hz range swept over 1 minute; 15 minutes per axis duration, unit shall operate without failure after vibration.
Mechanical
Single and dual chassis versions are offered.  
Front Panel Voltage and Current Control 10-turn voltage and current potentiometers
Front Panel Voltage Control Resolution

0.02% of maximum voltage

Front Panel Voltage and Current Meters 3-digit red numeric LED displays.
AC Input Connector Type IEC 15 A, 250 V
Input Fuses Non-user accessable, both lines fused
Output Connector Front panel: 5-way binding posts. Maximum current limit 30 A.
Rear panel: 7.5 to 18 V models: PCB bus bars with wire clamps; 33 to 120 V models: wire clamp connectors.
Sense Connector

Front panel: Standard 3/4" spaced test lead sockets
Rear panel: 5 terminal wire clamp connector (2 piece)

Analog Programming Connector 15 pin Female Dsub.
Chassis Ground Front panel binding post; chassis is grounded through power cord.
Cooling Fan cooled. Variable speed fan reduces to 50% when not required.
Mounting

Fits in 19" rack mount kit, which accommodates XPD, HPD, or XT units.

Maximum Dimensions Height: 5.25" (plus 0.3" for feet).
Width: Single output 4.24", dual output 8.5"
Depth: 13" (excluding front panel controls and front and back output terminals).
Weight Single output: 3.5 kg (7.7 lb.)
Dual output: 7 kg (15.4 lb.)
Agency Compliance CE-marked units meet IEC 1010-1 safety standard and EN50081-2 and EN50082-1 EMC standards. Additional standards: CSA C22.2 No. 1010.1, UL 3101, and FCC, part 15, class A EMI standard.