Performance You Need at a Price You Can Afford
Performance in an
Affordable Package
The TDS3000C Series digital phosphor
oscilloscopes (DPO) provide you with
the performance you need at a price
you can afford. Bandwidths range from
100 MHz to 500 MHz, with up to 5 GS/s
sample rates for accurate representation
of your signal.
DPOs Provide a Greater Level of
Insight into Complex Signals
To solve a problem, first you need to
see it.
The TDS3000C Series combines
3,600 wfms/s continuous waveform
capture rate and real-time intensity
grading so you can see the problem
and solve it.
Fast waveform capture rates on a
continuous basis save time by quickly
revealing the nature of faults so
advanced triggers can be applied to
isolate them.

Real-time intensity grading highlights
the details about the history of a signal’s
activity, making it easier to understand
the characteristics of the waveforms
you’ve captured. Unlike other comparable
oscilloscopes, the history remains
even after the acquisition is stopped.
Quickly Debug and Characterize
Signals with DRT Sampling
Technology and sin(x)/x Interpolation
The TDS3000C Series combines unique
digital real-time (DRT) sampling technology
with sin(x)/x interpolation to allow
you to accurately characterize a wide
range of signal types on all channels
simultaneously. With the TDS3000C
Series there is no change in sampling
rate when additional channels are
turned on, unlike other comparable
oscilloscopes. This sampling technology
makes it possible to capture
high-frequency information, such as
glitches and edge anomalies, that elude
other oscilloscopes in its class, while
sin(x)/x interpolation ensures precise
reconstruction of each waveform.
Digital Phophor Oscilloscope
Discover
and troubleshoot design problems faster with
TDS3000C Series’ 3,600 waveforms/second
continuous waveform capture rate and realtime
intensity grading. Continuous high waveform
capture rate saves time by quickly
revealing the nature of faults so advanced triggers
can be applied to isolate them.
Real-time intensity grading exposes the “history”
of a signal’s activity as they accumulate. The
digital phosphor display makes it easier to
understand the characteristics of the transients
you have captured. It intensifies the areas
where the signal trace occurs more frequently.
Digital Real-Time Sampling – Quickly debug
and characterize a wide range of signal types
on four channels simultaneously with Tektronix’
unique digital real-time (DRT) sampling technology.
This acquisition technology allows you
to capture high-frequency, non-repetitive information,
such as glitches and edge anomalies,
that elude other oscilloscopes.
Optional Application Modules – Transform
your oscilloscope into a specialized instrument
for limit testing, telecommunications mask
testing and video troubleshooting.
TDS3AAM Advanced Analysis Module
TDS3LIM Limit Testing Module
TDS3TMT Telecommunications Mask Testing Module
TDS3VID Extended Video Analysis Module
TDS3SDI 601 Serial/Digital Video Module
Simple Setup and Operation – Simplify setup
with Autoset function which adjusts controls to
produce a usable display of the input signal.
The most frequently used functions have been
brought forth to the panel for direct accessibility
(for example single sequence button, print button,
zoom and reference).
USB Host Port – Conveniently use your USB
flash drive to store your personal oscilloscope
setups, screen shots and waveform data for
later use. Also use the USB host port to easily
update your instrument firmware.
Waveform Measurements
Cursors – Amplitude, Time.
Automatic Measurements – Display any four
measurements from any combination of waveforms.
Or display all measurements with measurement
snapshot feature.
Measurements include Period,
Frequency, +Width, –Width, Rise time, Fall time,
+Duty cycle, –Duty cycle, +Overshoot, High, Low,
Max, Min, Peak-to-peak, Amplitude, Mean, Cycle
mean, RMS, Cycle RMS, Burst width, Delay, Phase,
Area, Cycle Area.

Measurement Statistics – Mean, Min, Max,
Standard deviation. Requires TDS3AAM application
module.
Thresholds – User-definable thresholds for automatic
measurements; settable in percent or voltage.
Gating – Isolate a specific occurrence within an
acquisition to take measurements, using either the
screen or cursors.
Waveform Math
Arithmetic – Add, subtract, multiply and
divide waveforms.
FFT – Spectral magnitude. Set FFT vertical scale
to Linear RMS or dBV RMS and FFT window to
Rectangular, Hamming, Hanning or Blackman-Harris.
Advanced Math – Integrate, Differentiate, Define
extensive algebraic expressions including analog
waveforms, math functions, scalars, up to two user
adjustable
variables and results of parametric measurements.
For example: (Intg (Ch1–Mean(Ch1)) x
1.414 x VAR1).
Waveform Processing
Autoset – Single-button, automatic setup of all
channels for vertical, horizontal and trigger systems,
with undo autoset.
Deskew – Channel-to-channel deskew +10 ns may
be manually entered for better timing measurements
and more accurate math waveforms.
WaveAlert for Enhanced Troubleshooting Ability.
WaveAlert waveform anomaly detection extends DPO's inherent fast
acquisition capability to speed your troubleshooting task by helping you
find those elusive problems faster. WaveAlert monitors the incoming
signals on all channels and highlights any waveform that deviates from
the normal waveform being acquired. The anomalous waveform is
highlighted in amber on screen and the user can select from several
alert actions the TDS3000C can take when an anomaly is detected: stop
acquisition, sound a beep, make a hardcopy, or save the waveform to disk
and continue. These actions allow you to run tests over long time
periods - even unattended - to find those challenging, very infrequent
failures. With WaveAlert waveform anomaly detection the TDS3000C is
watching for problems and alerts you when it finds them.
Optional battery operation
The TDS3BATC enables complete
portability independent of an AC line supply. This Lithium ion
battery pack provides up to 3 hours continuous operation.
Optional Application Modules
TDS3AAM Advanced Analysis Module
TDS3LIM Limit Testing Module
TDS3TMT Telecommunications Mask Testing Module
TDS3VID Extended Video Analysis Module
TDS3SDI 601 Serial/Digital Video Module
Included Accessories
All models include:
One P6139A 500 MHz 10x Passive Probe per Channel, Front Cover,
User Manual, OpenChoice® Desktop Software, National Instruments SignalExpress
Tektronix Edition LE Software, Calibration Certificate, Power Cord,
Accessory Bag. Three-year warranty (excluding probes).
Other Options
TDS3GV – GPIB, VGA,
RS-232 interface.
TDS3BATC – Lithium ion battery pack for up to 3 hours continuous
operation without line power.
TDS3CHG – Fast charger for battery pack.
AC3000 – Soft case for carrying instrument.
HCTEK4321 – Hard plastic case for carrying instrument (requires
AC3000).
RM3000 – Rackmount kit.
SIGEXPTE – NI LabVIEW SignalExpress™ Tektronix Edition Software
full version.
Service Manual – English only
TNGTDS01 – Extensive instructions and step-by-step lab exercises
provide education about the operation of TDS3000C
|