Tektronix Oscilloscope Probes and probe
products - available in the UK from TTi
|
|
|
|
|
- Passive Voltage Probes
- Active Voltage Probes
- Differential Voltage Probes
- Current Probes
|
|
|
| Passive
Voltage Probes |
|
|
Type |
Cable Length |
Atten
uation |
Bandwidth at -3 dB |
System Input Resistance |
Typical Input C |
Max Voltage |
Comp. Range |
Read Out |
ID/Gnd Ref. |
Tip/Head Style |
|
1X Passive Probe |
|
P6101B |
2 m |
1 |
15 MHz |
1 MOhms |
100 pF |
300 VRMS CAT I |
NA |
|
|
5 mm (Min.) |
|
10X Passive Probes |
|
P3010 |
2 m |
10 |
100 MHz |
10 MOhms |
13 pF |
420 VRMS CAT I |
15 to 35 pF |
X |
|
5 mm (Min.) |
|
P5050 |
1.3 m |
10 |
500 MHz |
10 MOhms |
11.1 pF |
300 VRMS CAT II |
16 to 22 pF |
X |
|
3.5 mm (Comp.) |
|
P5102 |
3.1 m |
10 |
100 MHz |
5 MOhms |
11.2 pF |
1000 VRMS CAT II |
24 to 28 pF |
|
|
Mono |
|
P6103B |
2 m |
10 |
60 MHz |
10 MOhms |
13 pF |
420 V CAT I |
15 to 35 pF |
|
|
5 mm (Min.) |
|
P6105A |
2 m |
10 |
100 MHz |
10 MOhms |
11 pF |
500 V CAT I |
15 to 35 pF |
X |
X |
5 mm (Min.) |
|
P6106A |
2 m |
10 |
250 MHz |
10 MOhms |
11 pF |
500 V CAT I |
15 to 35 pF |
X |
X |
5 mm (Min.) |
|
P6109B |
2 m |
10 |
100 MHz |
10 MOhms |
13 pF |
420 V CAT I |
15 to 35 pF |
X |
|
5 mm (Min.) |
|
P6111B |
2 m |
10 |
200 MHz |
10 MOhms |
14 pF |
420 V CAT I |
15 to 35 pF |
X |
|
5 mm (Min.) |
|
P6112 |
2 m |
10 |
100 MHz |
10 MOhms |
13.3 pF |
300 VRMS CAT II
420 VRMS CAT I |
15 to 35 pF |
|
|
5 mm (Min.) |
|
P6114B |
2 m |
10 |
400 MHz |
10 MOhms |
14.1 pF |
300 VRMS CAT II
420 VRMS CAT I |
10 to 35 pF |
X |
|
5 mm (Min.) |
|
P6117 |
2 m |
10 |
200 MHz |
10 MOhms |
13.3 pF |
300 VRMS CAT II
420 VRMS CAT I |
15 to 35 pF |
|
|
5 mm (Min.) |
|
P6131 |
1.3 m |
10 |
300 MHz |
10 MOhms |
10.8 pF |
300 VRMS CAT I
150 VRMS CAT II |
14 to 18 pF |
X |
|
2.5 mm (Sub.) |
|
P6133 |
2 m |
10 |
150 MHz |
10 MOhms |
12.7 pF |
300 VRMS CAT I
150 VRMS CAT II |
10 to 25 pF |
X |
|
2.5 mm (Sub.) |
|
P6134C |
1.5 m |
10 |
400 MHz |
10 MOhms |
11.3 pF |
500 VPk |
12 to 18 pF |
X |
X |
3.5 mm (Comp.) |
|
P6136 |
1.3 m |
10 |
350 MHz |
10 MOhms |
10.8 pF |
300 VRMS CAT I
150 VRMS CAT II |
12 to 18 pF |
X |
|
2.5 mm (Sub.) |
|
P6137 |
1.5 m |
10 |
400 MHz |
10 MOhms |
10.8 pF |
500 VPk |
12 to 18 pF |
X |
X |
3.5 mm (Comp.) |
|
P6138A |
1.3 m |
10 |
400 MHz |
10 MOhms |
10 pF |
300 VRMS CAT II
420 VRMS CAT I |
12 to 18 pF |
X |
|
3.5 mm (Comp.) |
|
P6139A |
1.3 m |
10 |
500 MHz |
10 MOhms |
8 pF |
300 VRMS CAT II |
8 to 12 pF |
X |
|
3.5 mm (Comp.) |
|
P6339A |
1.3 m |
10 |
500 MHz |
10 MOhms |
8 pF |
300 VRMS CAT II |
TDS 794D/694C |
X |
|
3.5 mm (Comp.) |
|
P6563A |
1.3 m |
20 |
500 MHz |
9.5 MOhms |
<5 pF |
42 VPk |
7 to 30 pF |
X |
|
SMD |
|
Type |
Cable Length |
Attenuation |
Bandwidth at -3 dB |
System Input Resistance |
Typical Input C |
Max Voltage |
Compen. Range |
Read Out |
ID/Gnd Ref. |
Tip/Head Style |
|
1X/10X Switchable |
|
P2200 |
1.5 m |
1/10 |
6/200 MHz |
1/10 MOhms |
110/17 pF |
300 VRMS CAT II |
15 to 25 pF |
X |
|
5 mm (Min.) |
|
100X/1000X High Voltage |
|
P5100 |
3.1 m |
100 |
250 MHz |
10 MOhms |
2.75 pF |
1,000 V CAT III
2500 Vdc + pkac
|
7 to 30 pF |
X |
|
Mono |
|
P6015A |
3.0 m |
1000 |
75 MHz |
100 MOhms |
3.0 pF |
20,000 V |
7 to 49 pF |
|
|
HVP |
|
P6015A Opt 1R |
3.0 m |
1000 |
75 MHz |
100 MOhms |
3.0 pF |
20,000 V |
7 to 49 pF |
X |
|
HVP |
|
P6015A Opt 25 |
7.6 m |
1000 |
25 MHz |
100 MOhms |
3.0 pF |
20,000 V |
7 to 49 pF |
|
|
HVP |
|
P6015A Opt 2R |
7.6 m |
1000 |
25 MHz |
100 MOhms |
3.0 pF |
20,000 V |
7 to 49 pF |
X |
|
HVP |
m = meters, V = volts, MHz = Megahertz, Mono. =
Monolithic, HVP = high voltage probe, pF = picofarads, mm =
millimeters. |
| Active
Voltage Probes |
|
Type |
Cable Length |
Attenuation |
Bandwidth at -3 dB |
System Input Resistance |
Typical Input C |
Max Voltage RMS |
Linear Range |
DC Offset Range |
ID/Gnd Ref. |
Tip/Head Style |
|
P6205 |
1.5 m |
10 |
750 MHz |
1 MOhms |
<2 pF |
±40 V |
±10 V |
N/A |
|
5 mm (Min.) |
|
P6241 |
1.3 m |
10 |
4 GHz |
40 kOhms |
<0.8 pF |
±30 V |
±4.0 V |
±10 V |
|
SMD Active |
|
P6243 |
1.3 m |
10 |
1 GHz |
1 MOhms |
<1 pF |
±15 V |
±8.0 V |
N/A |
|
SMD Active |
|
P6245 |
1.3 m |
10 |
1.5 GHz |
1 MOhms |
<1 pF |
±15 V |
±8.0 V |
±10 V |
|
SMD Active |
|
P6249 |
1.4 m |
5x |
4 GHz |
20 kOhms |
<1 pF |
±30 V |
±2.0 V |
±5 V |
|
SMD Active |
|
P6209 |
1.37 m |
5x |
4 GHz |
20 kOhms |
<1 pF |
±30 V |
±2.0 V |
±5 V |
|
SMD Active |
|
P7225 |
1.3 m |
10 |
2.5 GHz |
40 kOhms |
<0.8 pF |
±30 V |
±4.0 V |
±10 V |
|
SMD Active |
|
P7240 |
1.4 m |
5x |
4 GHz |
20 kOhms |
<1 pF |
±30 V |
±2.0 V |
±5 V |
|
SMD Active |
|
P7260 |
1.12 m |
5 |
6 GHz |
20 kOhms |
<0.5 pF |
±30 V |
±0.75 V |
±5 V |
|
SMD Active |
|
25 |
±3.0 V |
±5 V |
|
| Differential
Voltage Probes |
|
Type |
Cable Length |
Atten. |
B/W at -3 dB |
Diff. Input R |
Diff. Input C |
Max
Voltage RMS |
Diff. Input Voltage |
Common Mode Input Voltage |
Typical CMRR |
Interface
Style |
|
ADA400A |
|
X 100 |
1 MHz |
1 MOhms |
55 pF |
N/A |
±10 V |
0.01V |
>80 dB @ 10 kHz |
TEKPROBE |
|
X 10 |
±10 V |
1 V |
|
X 1 |
±40 V |
10 V |
|
X 0.1 |
±40 V |
80 V |
|
P5200 |
1.8 m |
50 |
25 MHz |
4 MOhms |
7 pF |
N/A |
1300 VRMS |
1000 VRMS CAT II |
>50 dB @ 1 MHz |
TEKPROBE |
|
500 |
|
P5205 |
1.8 m |
50 |
100 MHz |
4 MOhms |
7 pF |
N/A |
1300 VRMS |
1000 VRMS CAT II |
>50 dB @ 1 MHz |
TEKPROBE |
|
500 |
|
P5210 |
1.8 m |
100 |
50 MHz |
8 MOhms |
7 pF |
N/A |
4400 VRMS |
2200 VRMS CAT II |
>50 dB @ 1 MHz |
TEKPROBE |
|
1000 |
|
P6246 |
1.2 m |
1 |
400 MHz |
200 kOhms |
<1 pF |
±25 V |
±850 mV |
±7 V |
>60 dB @ 1 MHz |
TEKPROBE |
|
10 |
±8.5 V |
|
P6247 |
1.2 m |
1 |
1 GHz |
200 kOhms |
<1 pF |
±25 V |
±850 mV |
±7 V |
>60 dB @ 1 MHz |
TEKPROBE |
|
10 |
±8.5 V |
|
P6248 |
1.2 m |
1 |
1.5 GHz |
200 kOhms |
<1 pF |
±25 V |
±850 mV |
±7 V |
>60 dB @ 1 MHz |
TEKPROBE |
|
10 |
±8.5 V |
|
P6330 |
1.3 m |
5 |
3.5 GHz |
100 kOhms |
<0.3 pF |
±15 V |
±2 V |
+5 V to -4 V |
>60 dB @ 1 MHz |
TEKPROBE |
|
P7330 |
1.3 m |
5 |
3.5 GHz |
100 kOhms |
<0.3 pF |
±15 V |
±2 V |
+5 V to -4 V |
>60 dB @ 1 MHz |
TekConnect |
|
P7350 |
1.3 m |
6.25 |
5 GHz |
100 kOhms |
<0.3 pF |
±15 V |
±2.5 V |
+6.25 V to -5 V |
>45 dB @ 1 MHz |
TekConnect |
|
P7350SMA |
1.2 m |
6.25 |
5 GHz |
100 Ohms |
NA |
±15 V |
±2.5 V |
+6.25 V to -5 V |
>55 dB @ 1 MHz |
TekConnect |
|
| Current
Probes |
|
|
B/W Hz to MHz |
Peak Pulse |
Max ACP-P |
Derate Below |
Derate Above |
Max DC |
Amp-S Product |
I/Div Display Range |
Rise Time |
Insertion I/P @ 1 MHz |
Max Barewire Voltage |
Max Conductor Diameter |
Cable Length |
|
TCP300 and TCP400 Series Products For
TEKPROBE,
TekConnect and Standard 50 Ohms / 1 MOhms BNC Oscilloscope
Systems |
|
TCP312
w/TCPA300 |
DC to 100 |
50A |
60A |
N/A |
50 kHz |
5A - 1A/V
30A - 10A/V
|
50A*6uS - 1A/V
500A*6 uS - 10A/V
|
1A/V
10A/V |
<3.5 ns |
0.08 Ohms |
Insulated Wire Only |
3.8 mm
(0.15 in.) |
1.5 m |
|
TCP312
using CT4 |
0.5 to 20 |
20 kA*62 |
2 kA*63 |
50 Hz |
1.2 kHz |
20A |
0.5A*1S |
20A/V
10kA/V |
<17.5 ns |
2.5 mOhms |
3 kV |
38 mm
(1.5 in.) |
1.5 m |
|
TCP305
w/TCPA300 |
DC to 50 |
50A |
100A |
N/A |
2 kHz |
25A - 5A/V
50A - 10A/V |
500A*6µS - 5A/V
NA - 10A/V |
5A/V
10A/V |
<7 ns |
0.035 Ohms |
Insulated Wire Only |
3.8 mm
(0.15 in.) |
1.5 m |
|
TCP305
using CT4 |
0.5 to 20 |
20 kA*6 2 |
2 kA*63 |
50 Hz |
1.2 kHz |
20A |
5A*6S typ |
100A/V
10kA/V |
<17.5 ns |
1.1 mOhms |
3 kV |
38 mm
(1.5 in.) |
1.5 m |
|
TCP303
w/TCPA300 |
DC to 15 |
150A |
424A |
N/A |
1 kHz |
25 - 5A/V
150 - 50A/V |
3,000A*6µS - 5A/V
15,000A*6µS -
50A/V |
5A/V 50A/V |
<23 ns |
0.01 Ohms |
600V RMS CAT I & II
300V RMS CAT III |
21 mm x 25 mm
(0.83 x 1.0 in.) |
2 m |
|
TCP404XL
w/TCPA400 |
DC to 2 |
750A |
1414A |
N/A |
1.8 kHz |
750A*65 - 1A/mV
500A - 1A/mV
|
NA - 1A/mV |
1A/mV |
<175 ns |
0.1 mOhms |
600V RMS CAT I & II
300V RMS CAT III
|
21 mm x 25 mm
(0.83 x 1.0 in.)
|
8 m |
|
Direct Connect Current Probes |
|
TCP202 |
DC to 50 |
50 A |
40 A |
N/A |
20 kHz |
15 A |
500x10-6 |
*5 |
<7.0 ns |
0.07 Ohms |
300 V CAT I |
0.15 in. |
2.2 m |
|
TCP202 w/CT4 |
0.5 to 20 |
20 kA*3 |
2 kA*4 |
50 Hz |
1.2 kHz |
15 A |
0.1 |
*5 |
<17.5 ns |
30 mOhms |
3 kV |
1.5 in. |
2.2 m |
|
AM503B or AM5030 Amplifier Current Probes |
|
A6312 |
DC to 100 |
50 A |
40 A |
N/A |
20 kHz |
20 A |
100x10-6 |
1 mA to 5 A*2 |
<3.5 ns |
0.1 Ohms |
300 V CAT I |
0.15 in. |
2 m |
|
A6312 w/CT4 |
0.5 to 20 |
20 kA*3 |
2 kA*4 |
50 Hz |
1.2 kHz |
20 A |
0.1 |
20 mA to 5 kA*2 |
<17.5 ns |
30 mOhms |
3 kV |
1.5 in. |
2 m |
|
A6302 |
DC to 50 |
50 A |
40 A |
N/A |
20 kHz |
20 A |
100x10-6 |
1 mA to 5 A*2 |
<7.0 ns |
0.1 Ohms |
300 V CAT I |
0.15 in. |
2 m |
|
A6302 w/CT4 |
0.5 to 20 |
20 kA*3 |
2 kA*4 |
50 Hz |
1.2 kHz |
20 A |
0.1 |
20 mA to 5 kA*2 |
<17.5 ns |
30 mOhms |
3 kV |
1.5 in. |
2 m |
|
A6302XL |
DC to 17 |
50 A |
40 A |
N/A |
20 kHz |
20 A |
100x10-6 |
1 mA to 5 A*1 |
<20 ns |
0.1 Ohms |
300 V CAT I |
0.15 in. |
8 m |
|
A6302XL w/CT4 |
0.5 to 13 |
20 kA*3 |
2 kA*4 |
50 Hz |
1.2 kHz |
20 A |
0.1 |
20 mA to 5 kA*2 |
<20 ns |
30 mOhms |
3 kV |
1.5 in. |
8 m |
|
A6303 |
DC to 15 |
500 A |
200 A |
N/A |
20 kHz |
100 A |
10,000x10-6 |
5 mA to 50 A*2 |
<23 ns |
0.02 Ohms |
600 V CAT II |
0.83 in. |
2 m |
|
A6303XL |
DC to 10 |
500 A |
200 A |
N/A |
1.8 kHz |
100 A |
10,000x10-6 |
5 mA to 50 A*2 |
<35 ns |
0.02 Ohms |
600 V CAT II |
0.83 in. |
8 m |
|
A6304XL |
DC to 2 |
700 A |
700 A |
N/A |
1.8 kHz |
500 A |
0.4 |
500 mA to 200 A*2 |
<175 ns |
0.2 Ohms |
600 V CAT II |
0.83 in. |
8 m |
|
Other Current Probe Solutions |
|
P6021 |
120 to 60 |
250 A |
15 A |
300 Hz |
0.5 MHz |
0.5 A |
500x10-6 |
20 mA or 100 mA*2 |
<5.8 ns |
0.03 Ohms |
600 V |
0.15 in. |
1.5 m |
|
P6021 w/CT4 |
120 to 20 |
20 kA*3 |
2 kA*4 |
300 Hz |
1.2 MHz |
20 A |
0.5 |
400 mA or 100 A*2 |
<17.5 ns |
0.03 Ohms |
3 kV |
1.5 in. |
1.5 m |
|
P6022 |
935 to 120 |
100 A |
6 A |
3 kHz |
10 MHz |
0.2 A |
9x10-6 |
10 mA or 100 mA*2 |
<2.2 ns |
0.03 Ohms |
600 V |
0.10 in. |
2.75 m |
|
CT1 |
25 K to 1000 |
12 A |
1.4 A |
|
|
0.3 A |
1x10-6 |
2 mA*2 (5 mV/mA) |
<0.35 ns |
1 Ohms |
175 VRMS CAT I |
0.070 in. |
1.07 m |
|
CT2 |
1.2 K to 200 |
36 A |
7 A |
|
|
0.3 A |
50x10-6 |
10 mA*2 (1mV/mA) |
<0.5 ns |
0.1 Ohms |
175 VRMS CAT I |
0.052 in. |
1.07 m |
|
CT6 |
250 K to 2000 |
6 A |
0.7 A |
|
|
0.2 A |
0.25x10-6 |
2 mA (5mV/mA) |
<200 ps |
1.1 Ohms |
30 VRMS |
0.032 in. |
1 m |
*2 Scope set at 10 mV/Div.
*3 Based on voltage breakdown.
*4 Based on thermal heating limits in CT-4.
*5 Depends on instrument used.
*6 Derated w/ duty cycle and frequency. |
|
 |
|
|
|
|
|
|
|
Get More Information:
Please contact our sales desk and ask for a data sheet along with a
brochure covering other Tektronix products.
Alternatively use the buttons at the top to download a pdf file of the
data sheet, or use the Request Info button to request that one is sent to
you. |
|
Discuss an Application
or
Arrange a Demonstration:
Please contact our sales desk and ask to speak to one of our qualified
sales engineers.
They will be pleased to discuss the product and its use in your
application. They can also arrange a visit to demonstrate the
product. |
|
Place an Order
or get a Quotation:
A price list can be accessed using the buttons above.
Please contact our sales desk for quotations and current availability
information.
Many products are held in stock for immediate delivery. |
|
|
|
|
|
|
|
|
|
|

|
Thurlby Thandar
Instruments Ltd. Glebe Road, Huntingdon, Cambridgeshire
PE29 7DR
Tel: 01480 412451 Fax:
01480 450409 Email: sales@tti.co.uk Web:
http://www.tti.co.uk |
| |
|
|