Take Control of Your AC Test Power
The ASX Series is a family of High Performance Switching AC
power sources covering the power range from 1.5kVA to 6kVA
(12kVA to be released soon). The product line offers both
single and three phase models. Units are conservatively
designed and output power ratings are based on the most severe
combination of input line, output voltage, power factor, and
temperature.
Great emphasis has been placed on low acoustic noise, ease
of installation, and maximum power per cubic inch of rack
space. Control and operational features provide a high degree
of application versatility and ease of use for the test
engineer. Applications range from simple, manually controlled
frequency conversion to harmonic testing and sophisticated bus
programmable transient simulation.
Power conversion within the ASX Series is achieved by high
frequency pulse width modulation, resulting in cool, quiet and
efficient operation.
Key Features Provide Application Versatility
-
22 Waveform Library - Arbitrary Waveform Generator
-
15 to 1,200 Hz Operation - 5,000 Hz Bandwidth
-
Precision True-RMS metering of volts, amps, and
power for displays and reporting
-
RS-232 Interface with SCPI compatibility
-
1 Phase/3 Phase Switch Selectable Output from
front panel or bus command
-
99 stored programs for both static and dynamic
Transient Testing
-
LabVIEW for Windows®/LabWindows® drivers
-
Waveform Creation by Harmonic Synthesis
|
 |
-
Harmonic Analysis (Voltage and Current)
-
Metering of RMS and Peak Values
-
Continuous Self Calibration (CSC)
-
Precision Voltage Programming - 0.05% with CSC
engaged
-
Programmable Output Impedance
-
Up to 0-300 VAC Direct Coupled Out
-
Power Levels from 1.5 kVA to 12 kVA
-
Externally Referenced Meter Calibration
-
CE and ETL Mark available
-
Design Provides Total Control of AC Power
|
Design Provides Total Control of AC Power
-
All ASX Series power source models may be equipped with a
digitally programmable Oscillator/Controller or a manual
version.
-
Single phase power source models may be controlled to
operate on either a 0-135 VAC range or a 0-270 VAC range.
Three phase models are additionally switchable 3ø to 1ø
output power form.
-
Total control of the output power form and the selection
of either the direct output or the optional transformer
output is available from the front panel or the bus.
-
All operating functions may be controlled from either the
front panel or from a remote RS-232 or IEEE 488.2/ SCPI BUS.
LabVIEW for Windows® and LabWindows® Instrument Drivers are
available.
Special ASX Series Operating
Features
Continuous Self
Calibration Provides for exceptional accuracy of
the AC output Voltage. When enabled, accuracy improves to
±0.1% referenced to the power source internal
voltmeter.
Programmable Dynamic Output
Impedance - Prog-Z (optional on
UPC1/3) Programmable Output Impedance provides the
operator with the ability to dynamically control the output
impedance of the AC Power Source. Using the output current
term as conditioned feedback signal to the output voltage
circuits, positive or negative impedance may be programmed.
This control simulates the effects of, or compensates for high
peak current, distribution, or transformer losses of up to
±10% of the output voltage.
This feature creates positive, negative, or zero output
impedance (Zo).
Waveform Library Up to 22 different
waveforms can be stored in the waveform library for execution
as part of a steady state program or for substitution in any
output phase as part of a transient test program. Memory
location #1 is a non-editable high resolution sine wave.
Locations 2-22 are editable and can be substituted in any
output phase. An unlimited number of waveforms may be stored
on the computer for those using a programmable UPC.
Waveform Edit A full-featured editor
permits modification of a stored waveform in both time and
frequency domains. This method can be used to quickly create
spikes, dropouts, notches and other sub-cycle wave conditions.
The resulting modified waveform is stored for execution in
steady-state or transient programs.
Waveform Analysis (optional on UPC1/3)
Provides both graphic (using LabView for WindowsT) and
numeric displays of the harmonic structure of a voltage or
current waveform. Each waveform is analyzed for its harmonic
content up to the 51st harmonic. Amplitude and phase are
reported to the local display. The LabVIEWT instrument driver
displays numeric values as well as a graphic summary of the
harmonic spectrum.
Waveform Synthesis (optional on
UPC1/3) Quickly create virtually any AC test
waveform by building it out of harmonics. The process is as
simple as keying in the magnitude and phase angle of each
desired harmonic up through the 51st. Additionally, waveforms
can be created by downloading from a host PC.
Time Based Transients Create and
execute transients that occur over a specified time segment to
modify the output waveform, voltage, and frequency for any or
all phases. An output trigger is provided for synchronizing
external test equipment to the actual transient event.
Cycle Based Transients Create and
execute transients that substitute a waveform in any or all
phases for 1 to 100 cycles. The waveform being substituted can
be selected and/or modified from the waveform
library.
ASX Series AC Power
Sources
|
MODEL |
RATED POWER (VA) |
OUTPUT
FORM
NOTE 1 |
OUTPUT
VOLTS- MAX (Vrms)
NOTE
2 |
OUTPUT
AMPS (Arms)
NOTE 3 |
OUTPUT
AMPS (Apeak) |
INPUT POWER FORM
NOTE
4 |
PANEL HEIGHT (U) |
WEIGHT
(LBS./KG.) |
|
115ASX |
1500 |
1Ø |
132 |
16 |
35 |
1Ø |
3 |
65/30 |
|
120ASX |
2000 |
1Ø |
150/300 |
20/14 |
90/45 |
1Ø |
3 |
75/34 |
|
140ASX |
4000 |
1Ø |
135/270 |
32/16 |
90/45 |
3Ø* |
5 |
120/55 |
|
315ASX |
1500 |
1Ø 3Ø |
132/264 132 (Vl-N) |
12/6 4 per Ø |
69/23 23 per Ø |
1Ø |
3 |
60/27 |
|
320ASX |
2000 |
1Ø 3Ø |
135/270 135 (Vl-N) |
20/12 7 per Ø |
69/23 23 per Ø |
1Ø |
3 |
85/37 |
|
345ASX |
4500 |
1Ø 3Ø |
135/270 135 (Vl-N) |
36/12 12 per Ø |
100/40 40 per Ø |
3Ø* |
5 |
170/77 |
|
360ASX |
6000 |
1Ø 3Ø |
135/270 135 (Vl-N) |
48/16 16 per Ø |
210/70 70 per Ø |
3Ø* |
5 |
180/82 |
|
3120ASX |
12000 |
1Ø 3Ø |
135/270 135 (Vl-N) |
96/32 32 per Ø |
300/100 100 per Ø |
3Ø |
9 |
340/154 |
Notes:
All single phase output units (Model 115 ASX excepted)
are operable with dual voltage ranges as listed. Three phase
units are operable as single phase with dual voltage range
capability or as three phase. Output voltage ranges and
1ø/3ø conversions are selected by front panel or bus
commands.
Output voltage ranges listed are for standard units. VMAX
is output voltage with nominal input and full rated load
applied. Other voltage ranges are available with the output
magnetics options below.
Peak Repetitive Pulse Current.
Single phase input: 100, 110, 120, 208, 220 and 240 VAC
±10%. Three phase input: 208,220,240,380,416 and 480 VAC ±
10%. (480 V input and 400 Hz input are each available as a
cost option.) *Single phase version available for added
cost.
Applications
AC
Test Power The ASX Series Power Source is equipped
with a powerful microcontroller to create a fully integrated
test system. It supplies a variety of power conditions to the
device under test and meters/analyzes all output performance
parameters.
Frequency/Voltage
Conversion The ASX Series is an excellent source
of stable AC voltage over the frequency range of 15 to 1,200
Hz. The output frequency is quartz-crystal stabilized. Output
voltages up to 600 VAC are provided.
Phase
Conversion With the ability to provide singe and
three-phase outputs, the ASX Series is the perfect choice to
provide 1 Phase to 3 Phase or 3 Phase to 1 Phase
conversion.
Controller Selection Guide
Six controller models are available with the ASX-Series.
They include 1 Phase and 3 Phase models for both manual and
programmable control.
-
UPC-1M, 1 Phase Manual Control, 15 Hz to 1,200 Hz.
-
UPC-3M, 3 Phase Manual Control, 15 Hz to 1,200 Hz.
-
UPC-3EM, 3 Phase Manual Control, 15 Hz to 599 Hz.
-
UPC-1, 1 Phase Programmable Control, 15 Hz to 1,200 Hz.
-
UPC-3, 3 Phase Programmable Control, 15 Hz to 1,200 Hz.
-
UPC-3E, 3 Phase Programmable Control, 15 Hz to 599 Hz.
All controllers provide manual operation from the front
panel. Programmable Controllers may be programmed from the
front panel or from a remote interface. RS232 Interface is
standard. IEEE 488 interface is optional.
Power Source
Specifications
Output Frequency: 15
to 1,200 Hz. Full Power
Line
Regulation: 0.1% max for a ±10% line
change.
Load Regulation: 0.25% 15
to 400 Hz., 0.50% 400 to 1,200 Hz. With external sense
enabled. Improves to less than 0.1% with external sense and
CSC enabled.
Output
Distortion: 0.25% THD 15 to 200 Hz., 0.50% THD 200
to 1,200 Hz.
Ripple and Noise: -66
dB
Response Time: 60 microseconds
typical, 10-90% load step.
Mechanical
Specifications
All models are designed for
operation in 19 inch equipment racks. Models 4 kVA and higher
have side handles for ease of
handling.
Mounting: Standard 19
inch rack. Slide rails are available as an option for all
models.
Height: See model table
above for panel
height.
Depth: Approximately 24
inch, from the front panel to the rear of the
chassis.
Cooling: Front or side
forced air intake with rear exhaust. Automatic Fan Speed
Control for low acoustic noise and extended fan life.
Dual Range Output Magnetics
Options
ASX Series Power Sources can be equipped
with output transformers to provide an alternate output
voltage range. Selection of direct or transformer coupled
range is performed by the controller via front panel or bus
command. The standard frequency range for transformer coupled
outputs is 45 to 1,200 Hz. Standard output ratios are 1.5:1,
2.0:1, and 2.5:1. Transformer outputs are supplied internally
or externally via a Magnetics Module as listed in the above
table. Consult the factory for additional information
regarding special output ranges not listed above.
UPC Series Controller
Specifications
The latest additions to Pacific's
SmartsourceT family of UPC Controllers are the UPC-1M, UPC-3M,
UPC-1 and UPC-3. The UPC Controller is a modular component of
the ASX Series and is available in four configurations ranging
from 1 Phase to 3 Phase and Manual Control to Programmable
Control. The table below lists each model according to key
features.
All UPC Controllers include precise metering
functions with data displayed via a 160 character LCD display.
This, along with the 30-key front panel, provides the
industry's most powerful and user-friendly
controller.
The UPC-1 and UPC-3 controllers are
available with either the RS-232 or GPIB remote interface.
Commands are structured in accordance with SCPI (Standard
Commands for Programmable Instruments). The RS-232 serial port
operates up to 38.4 Bps. The GPIB interface is compatible with
the IEEE-488.2.
Frequency: Range:
15 to 1,200 Hz. Resolution: 4 significant digits, eg. 50.00,
400.0, etc. Accuracy: ±0.01%, 15 to 1,200
Hz
Voltage: Range: 0 to Vmax in 0.1
VAC steps. Accuracy: Executive voltage is within ±50 mVAC
(0.05%) of command voltage referenced to the internal
voltmeter with CSC engaged.
Phase
Angle: Phase Separation of Phases B and C are
programmable 0 to 360° relative to phase A on the UPC-3
controller. Phase separation is fixed at 120° and 240°,
respectively, on the UPC-3M
controller.
Programmable Current
Limit: Programmable Current limit is provided on
the UPC-1 and the UPC-3 controllers. Programmable range is
from 0 to Ipeak, max of the power
source.
Output Voltmeter: The
Output Voltmeter is true RMS reading and each phase is
measured independently. Line to neutral and line to line
voltages are displayed. Range: 0-354 VACL-N, 0-708 VACL-L.
Resolution: 0.1 VAC to front panel, 0.001 VAC to remote
interface. Accuracy: ±0.2% of range + cal.
ref.
Output Ammeter: Output Ammeter
is true RMS reading and each phase is measured independently.
RMS and peak currents along with Crest factor are displayed.
Range: 300% of system current rating. Resolution: 0.01 AAC to
front panel, 0.001 AAC to remote interface. Accuracy: ±0.2% of
range + cal ref.
Power: Measures
True Power (kW), Apparent Power (kVA) and power factor. Range:
Based on ammeter. Resolution: 1.0 watts or VA to front panel,
1.0 watts or VA to remote interface.
Power
Factor: Calculated and displayed to three
significant digits.
Expanding the AC Power Source into an
Automated Test System
Pacific's line of SmartsourceT AC Power Sources enable the
engineer to easily automate his testing by using Lab VIEW for
WindowsT or LabWindowsT. An extensive list of Virtual
Instruments (VIs) are offered for Pacific's ASX Series Power
Sources.
Specifications subject to change without
notice. |