Take Control of Your AC Test Power
The AMX Series is a family of High Performance Linear AC
power sources covering the power range from 500 VA to 12 kVA
with standard models and up to 30 kVA with optional M5283
option. The product line offers both single and three phase
models. Units are conservatively designed and output power
ratings are based on the most severe combination of input
line, output voltage, power factor, and temperature. This
approach to product design allows the AMX Series to excel when
delivering the high peak load currents demanded in the AC test
environment.
Great emphasis has been placed on low acoustic noise, ease
of installation, and maximum power per cubic inch of rack
space. Control and operating features provide a high degree of
application versatility and ease of use for the test engineer.
Applications range from simple, manually controlled frequency
conversion to harmonic testing and sophisticated bus
programmable transient simulation.
An exceptionally broad bandwidth (50 kHz small signal)
combined with peak/RMS current of 4-6:1 give the AMX Series
the ability to produce high quality, low distortion output
power into the most dynamic loads.
Key Features Provide Application
Versatility
-
IEEE-488.2 or RS-232C with SCPI compatibility
-
LabVIEW for Windows®/LabWindows® drivers
-
Waveform Creation by Harmonic Synthesis
-
Graphical Analysis (Voltage and Current)
-
Harmonic Analysis (Voltage and Current)
-
Metering of RMS and Peak Values
-
Continuous Self Calibration (CSC)
-
Line Sync Option
-
6:1 Peak Current Capability |
 |
-
Low Impedance for EN61000-3-2, 3 Testing
-
Programmable Output Impedance
-
Up to 0-300 VAC Direct Coupled Out
-
1 Phase / 3 Phase Switch Selectable
-
20-5000 Hz Full Power Bandwidth
-
Power Levels from 500 VA to 12 kVA standard; 30kVA
optional
-
Externally Referenced Meter Calibration
-
CE and ETL Mark available
|
Design Provides Total Control of AC Power
-
All AMX Series power source models may be equipped with
either a digitally programmable Oscillator/Controller (UPC
type) or a manually controlled Oscillator (UMC type).
-
Single phase power source models may be controlled to
operate on either a 0-135 VAC range or a 0-270 VAC range.
Three phase models are additionally switchable to 3ø/1ø
output power form.
-
Total control of the output power form and the selection
of either the direct output or the optional transformer
output is available from the front panel or the bus.
-
All operating functions may be controlled from either
the front panel or from a remote RS-232 or IEEE 488.2/ SCPI
BUS. LabVIEW for Windows® and LabWindows® Instrument Drivers
are available.
Special AMX Series Operating Features
Continuous Self Calibration Provides
for exceptional accuracy of the AC output Voltage. When
enabled, accuracy improves to ±0.03% referenced to the power
source internal voltmeter.
Programmable Dynamic
Output Impedance (optional on
UPC12/32) Programmable Output Impedance provides
the operator with dynamic control over the output impedance of
the AC Power Source. Using the output current term as
conditioned feedback signal to the output voltage circuits,
positive or negative impedance may be programmed. The purpose
of this control is to simulate the effects of or compensate
for high peak current, distribution, or transformer losses of
up to ±10% of the output voltage.
This feature creates positive, negative, or
zero output impedance (Zo).
Waveform Library Up to 16 different
waveforms can be stored in the waveform library for execution
as part of a steady state program or for substitution in any
output phase as part of a transient test program. Memory
location #1 is a non-editable high resolution sine wave.
Locations 2-16 are editable and can be substituted in any
output phase. An unlimited number of waveforms may be stored
on the computer for those using a programmable
UPC.
Waveform Edit Provides the
ability to modify a stored waveform by specifying the waveform
amplitude desired at each specific phase
angle.
Waveform Analysis (optional on
UPC12/32) Provides both a graphic and numeric
display of the harmonic structure of a voltage or current
waveform. Data presented includes the magnitude of each
harmonic in %, the total harmonic distortion, and the odd and
even harmonic distortion in %.
Waveform
Synthesis (optional on UPC12/32) Provides the
ability to quickly create virtually any AC Test Waveform that
may be required by building it out of harmonics. The process
is as simple as keying in the harmonic multiple, the
amplitude, and the phase angle for each desired harmonic up
through the 51st.
Time Based
Transients Provide the ability to create and
execute on command, transients that occur linearly over a
specified time segment to modify output voltage or
frequency.
Cycle Based
Transients Provide the ability to create and
execute, on command, transients that substitute a selected
waveform in the output for 1 to 100 cycles.
AMX AC Power Sources
|
MODEL |
RATED POWER (VA) |
OUTPUT
FORM
NOTE 1 |
OUTPUT
VOLTS- MAX (Vrms)
NOTE
2 |
OUTPUT
AMPS (Arms)
NOTE 3 |
OUTPUT
AMPS (Apeak) |
INPUT POWER FORM
NOTE
4 |
PANEL HEIGHT (U) |
WEIGHT
(LBS./KG.) |
|
105AMX |
500 |
1Ø |
135/270 |
4/2 |
40/20 |
1Ø |
3 |
60/27 |
|
108AMX |
750 |
1Ø |
135/270 |
6/3 |
40/20 |
1Ø |
3 |
60/27 |
|
112AMX |
1200 |
1Ø |
150/300 |
10/5 |
40/20 |
1Ø |
3 |
70/32 |
|
125AMX |
2500 |
1Ø |
150/300 |
20/10 |
90/45 |
3Ø* |
6 |
110/50 |
|
140AMX |
4000 |
1Ø |
135/270 |
32/16 |
140/70 |
3Ø* |
8 |
170/77 |
|
305AMX |
500 |
1Ø 3Ø |
135/270 135 (Vl-N) |
4/2 1.5 per Ø |
45/15 15 per Ø |
1Ø |
3 |
60/27 |
|
308AMX |
750 |
1Ø 3Ø |
135/270 135 (Vl-N) |
6/2 2 per Ø |
45/15 15 per Ø |
1Ø |
3 |
60/27 |
|
312AMX |
1200 |
1Ø 3Ø |
150/300 150 (Vl-N) |
10/3.3 3.3 per Ø |
45/15 15 per Ø |
1Ø |
3 |
70/32 |
|
320AMX |
2000 |
1Ø 3Ø |
135/270 135 (Vl-N) |
18/6 6 per Ø |
60/20 20 per Ø |
3Ø |
5 |
125/57 |
|
345AMX |
4500 |
1Ø 3Ø |
135/270 135 (Vl-N) |
36/12 12 per Ø |
165/55 55 per Ø |
3Ø |
8 |
170/77 |
|
360AMX |
6000 |
1Ø 3Ø |
135/270 135 (Vl-N) |
48/16 16 per Ø |
210/70 70 per Ø |
3Ø |
8 |
180/82 |
|
390AMX |
9000 |
1Ø 3Ø |
135/270 135 (Vl-N) |
72/24 24 per Ø |
330/110 110 per Ø |
3Ø |
16 (2 x 8) |
340/154 |
|
3120AMX |
12000 |
1Ø 3Ø |
135/270 135 (Vl-N) |
96/32 32 per Ø |
420/140 140 per Ø |
3Ø |
16 (2 x 8) |
360/163 |
Notes:
All single phase units are operable with dual voltage
ranges as listed. All three phase units are operable as
single phase with dual voltage range capability or as three
phase. Output voltage ranges and 1ø / 3ø conversions are
selected by front panel or bus command.
Output voltage ranges listed are for standard units.
VMAX is achievable with nominal input voltage at full load.
Other voltage ranges are available with the output magnetics
option.
Current ratings at 125 VRMS output.
Input power frequency is 47-63 Hz (400Hz optional).
Single Phase: 100, 110, 120, 200, 208, 220, 230, 240, VAC ±
10%. Three phase: 208, 220, 240, 380, 416 VAC ± 10%. *Single
phase version available for added cost.
Applications
AC
Test Power The AMX Series Power Source is equipped
with a powerful microcontroller to create a fully integrated
test system. It supplies a variety of power conditions to the
device under test and meters/analyzes all output performance
parameters.
Frequency/Voltage Conversion The AMX
Series is an excellent source of stable AC voltage over the
frequency range of 20 to 5,000 Hz. The output frequency is
quartz-crystal stabilized. Output voltages up to 600 VAC are
provided.
Phase Conversion With the
ability to provide singe and three-phase outputs, the AMX
Series is the perfect choice to provide 1 Phase to 3 Phase or
3 Phase to 1 Phase conversion.
Controller Selection Guide
Four controller models are available with the AMX-Series.
They include 1 Phase and 3 Phase models for both manual and
programmable control.
-
UMC-31, 1/3 Phase Manual Control, 45 Hz to 500 Hz.
-
UPC-12, 1 Phase Programmable Control, 20 Hz to 5,000 Hz.
-
UPC-32, 3 Phase Programmable Control, 20 Hz to 5,000 Hz.
-
UPC-32E, 3 Phase Programmable Control, 20 Hz to 599.9
Hz.
All controllers provide manual operation from the front
panel. Programmable Controllers may be programmed from the
front panel or from a remote interface. IEEE 488 interface is
standard. RS232 interface is optional.
Dual Range Output Magnetics Options
AMX Series Power Sources can be equipped with output
transformers to provide an alternate output voltage range.
Selection of direct or transformer coupled range is performed
by the controller via front panel or bus command. The standard
frequency range for transformer coupled outputs is 45 to 5,000
Hz. Standard output ratios are 1.5:1, 2.0:1, and 2.5:1.
Transformer outputs are supplied internally or externally via
a Magnetics Module as listed in the above table. Consult the
factory for additional information regarding special output
ranges not listed above.
Power Source Specifications
Output Frequency: 20 to 5000 Hz. Full
Power
Line Regulation: 0.1% max for
a 10% line change
Load
Regulation: 0.25% 20 to 2000 Hz. 0.5% 2000 to 5000
Hz. Can be improved to less than 0.03% with CSC
engaged.
Output Distortion: 0.1%
THD from 20 to 1000 Hz 0.25% THD from 1000 to 5000
Hz
Ripple and Noise: -72
dB
Response Time: 5µsec. typical to
a step load change. Small signal band-width is 5 Hz. to 50
kHz, typical.
Mechanical Specifications
All models are designed for operation in 19 inch equipment
racks. Models above 1800 VA have side handles for ease of
handling.
Mounting: Standard 19
inch rack. Slide rails are available as an option for all
models.
Height: See model table
above for panel height.
Depth: Will
not exceed 24 inches from the front panel to the rear of the
chassis, including connectors, handles and
cabling.
Cooling: Forced air, front
or side intakes, rear exhaust with auto fan speed control for
low acoustic noise operation.
UPC Controller Specifications
The UPC controller is essentially a single or three phase
AC arbitrary waveform generator and Precision AC metering
system. The waveform for each phase may be independently
selected and may be independently varied in amplitude and
phase angle with respect to phase A (3 phase
systems).
The UPC output metering samples the output
volts and amps at 512 samples per measurement using a 12 bit
A/D converter. This technique provides exceptional metering
accuracy and resolution (20 bits), and delivers a
high-fidelity waveform back to a host computer for
analysis.
The UPC includes a remote GPIB interface
compatible with IEEE 488.2 and SCPI. An available option is an
RS-232 serial port that operates up to 38.4
kBaud.
Frequency: 20.00 to 5000 Hz
±0.01%
Voltage
(Direct): Programmable, 0-VMAX, in 0.1 volt steps
(see table)
Phase Angle: Phase
Angle (f) of Phases B and C relative to Phase A is
programmable from 0-359° in 1° increments ±
0.5°.
Current Limit: Current limit
is programmable from 0 to I peak maximum of the power source.
Accuracy is ± 1%, resolution ± 0.05%.
Waveform
Library: Stores up to 15 waveforms that can be
edited and executed in any manner and in any output
phase.
Voltmeter: Range: 0-354
volts L-N, 0-708 volts L-L Resolution: 0.10VAC to front
panel, 0.001VAC to remote interface Accuracy: ± 0.25% of
reading ± 0.1% of range
(50-500Hz)
Ammeter: Range: 300% of
system current rating Resolution: 0.01AAC to front panel,
0.001AAC to remote interface Accuracy: ± 0.25% of reading ±
0.1% of range (50-500Hz)
Power
Meter: Range: Based on ammeter
range Resolution: 1.0 watts or VA to front panel, 0.001
Watts or VA to remote interface Accuracy: ± 1% of Full
Scale
Power Factor & Crest
Factor: Calculated and displayed to three
significant digits.
Expanding the AC Power Source into an Automated
Test System
Pacific's line of SmartsourceT AC Power Sources enable the
engineer to simply automate his testing by using Lab VIEW for
WindowsT or LabWindowsT. An extensive list of Virtual
Instruments (VIs) are offered for Pacific's AMX Series Power
Sources.
Manual Control of AC Power

Provide easy manual control with Pacific's
UMC-31 Manual AC Power Controller.
-
Obtain precision frequency and phase conversion for
manufacturing and test
-
Provide high quality, general purpose lab power where
test versatility is required
-
Achieve low cost and power form flexibility for power
supply tests.
The UMC-31 provides operational control and high quality
oscillator signals for both single and three phase Power
Sources.
Specifications UMC-31
Controller
Phase: Select
single, split, or three phase operation by internal jumper.
Phase angles are fixed at 120° and 240° for three phase
operation.
Frequency: Select 50,
60, or 400 Hz fixed or a variable frequency mode of 45 to 500
Hz.
Voltage: 0-VMAX via 10 turn
potentiometer on the front
panel.
Metering: Autoranging Volts,
Amps, and Frequency.
Specifications are subject to change without
notice. |