Accuracy and diagnostic functions for maximum industrial
productivity
The new Fluke 87V has improved measurement functions,
trouble-shooting features, resolution and accuracy to solve
more problems on motor drives, in plant automation, power
distribution and electro-mechanical equipment.
The New 80 Series consists on the following models:
Fluke 83 V Industrial DMM
Fluke 87 V True RMS Industrial DMM
Fluke 87 V/E Industrial
Electricians Combo Kit
The 80 Series V operates very similar to the classic 80
series, but with more problem solving power, safety,
convenience and impact protection.
The new 80 series V are independently tested to comply with
the 2nd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV
600V/CAT III 1000V. They can withstand impulses in excess of
8,000 V and reduce risks related to surges and spikes.
| Specifications |
| Voltage DC |
| Maximum Voltage: |
1000V |
| Accuracy: |
Fluke 83 V: ±(0.1%+1) |
|
Fluke 87 V:
±(0.05%+1) |
| Maximum Resolution: |
Fluke 83 V: 100 µV |
|
Fluke 87 V: 10
µV | |
| Voltage AC |
| Maximum Voltage: |
1000V |
| Accuracy: |
Fluke 83 V: ±(0.5%+2) |
|
Fluke 87 V: ±(0.7%+2) True
RMS |
| AC Bandwidth |
Fluke 83 V: 5kHz |
|
Fluke 87 V: 20kHz* |
|
*with low pass filter; 3db
@ 1kHz |
| Maximum Resolution: |
0.1
mV | |
| Current DC |
| Maximum Amps: |
10A (20 A for 30 seconds
maximum) |
| Amps Accuracy: |
Fluke 83 V: ±(0.4%+2) |
|
Fluke 87 V: ±(0.2%+2) |
| Maximum Resolution: |
Fluke 83 V: 0.01 mA |
|
Fluke 87 V: 0.01
µA | |
| Current AC |
| Maximum Amps: |
10A (20 A for 30 seconds
maximum) |
| Amps Accuracy: |
Fluke 83 V: ±(1.2%+2) |
|
Fluke 87 V: ±(1.0%+2) True
RMS |
| Maximum Resolution: |
0.1
µA | |
| Resistance |
| Maximum Resistance: |
50 MΩ |
| Accuracy: |
Fluke 83 V: ±(0.4%+1) |
|
Fluke 87 V: ±(0.2%+1) |
| Maximum Resolution: |
0.1Ω | |
| Capacitance |
| Maximum Capacitance |
9,999 µF |
| Accuracy |
±(1%+2) |
| Maximum Resolution |
0.01
nF | |
|
Frequency |
| Maximum Frequency |
200 kHz |
| Accuracy |
±(0.005%+1) |
| Maximum Resolution |
0.01
Hz | |
| Duty Cycle |
| Maximum Duty Cycle |
99.9% |
| Accuracy |
±(0.2% per khz +0.1%) |
| Maximum Resolution |
0.1% | |
| Temperature
Measurement |
| Fluke 87 V, 87 V/E: |
-200.0°C - 1090°C |
|
-328.0°F - 1994.0°F |
|
excluding
probe | |
| 80 BK Temperature
Probe |
|
-40.0°C - 260°C |
|
-40.0°F - 500°F, 2.2°C or
2% whichever is greater | |
| Conductance |
| Maximum Conductance |
60.00 nS |
| Accuracy |
±(1.0%+10) |
| Maximum Resolution |
0.01
nS | |
| Diode |
|
Range 3 V |
| Resolution: |
1 mV |
| Accuracy: |
± (2 % +
1) | |
| Duty Cycle Range |
| Accuracy: |
Within ± (0.2% per kHz +
0.1 %) | |
| Safety
Specifications |
| Overvoltage category |
|
EN 61010-1 to 1000 V CAT
III, 600V CAT IV | |
| Agency Approvals |
|
| Mechanical &
General Specifications |
| Size |
|
201 x 98 x 52 mm (with
holster) | |
| Weight
|
|
| Weigh With Holster and
Flex-Stand |
|
| Display |
| Digital: |
6000 counts updates
4/sec. |
|
(Model 87 also has 19,999
counts in high-resolution mode.) |
| Analog: |
32 segments, updates
40/sec. |
| Frequency: |
19,999 counts, updates
3/sec at > 10 Hz. | |
| Warranty |
|
| Battery Life |
| Alkaline: |
~400 hours typical, without
backlight | |
| Shock |
|
1 Meter drop per IEC
61010-1:2001 | |
| Vibration |
|
Per MIL-PRF-28800 for a
Class 2
instrument | |
|