The Fluke Handheld Test Tools range is available from TTi in the UK
|
|
|
Fluke 43 Power Quality Analyser -
Specifications
|
|
|
|
|
- Voltage, current, and power harmonics
- Up to 51st harmonic
- Total harmonic distortion (THD)
- Phase angle of individual harmonics
- Watts, power factor, displacement power factor, VA and VAR
- Voltage and current waveforms
- Continuously measure volts and amps on a cycle-by-cycle basis for up to
16 days
|
|
|
| Power |
Line voltage adapter/battery charger included |
| Installed battery |
Rechargeable Ni-Cd pack |
| Operating time |
4 hours |
| Charging time |
4 hours |
| Environmental |
| Temperature |
0°C to 50°C (32°F to 122°F) |
| Environmental |
MIL 28800E, Type 3, Class III, Style B |
| Enclosure |
IP51 (dust, drip water proof) |
| Mechanical Data |
| Size: (H x W x D) |
232 x 115 x 50 mm (9.1 x 4.5 x 2 inches) |
| Weight |
1.1 kg (2.5 lbs.) |
| Safety |
| Surge protection |
6 kV on input A and |
| Floating measurements |
600V rms from any terminal to ground |
| Warranty |
3 years parts and labor on Fluke 43, 1 year on
accessories |
| Technical Data |
| Input Characteristics |
| Input impedance |
1 MOhm, 20 pF |
| Voltage Rating |
600V rms, CAT III |
| Volt/Amps/Hertz
Display |
| True-rms voltage (ac+dc) |
Ranges: 5.000V, 50.00V, 500.0V,
1250V*
Accuracy: ±(1% +10 counts) |
| True-rms current (ac + dc) |
Ranges: 50.00A, 500.0A, 5.000 kA,
50.00 kA
Accuracy: ±(1% +10 counts) |
| Mains frequency |
Ranges: 40.0 to 70.0 Hz
Accuracy: ±(0.5% +2 counts) |
| Power Display |
| Watts, VA, VAR |
Ranges: 250 W, 2.50 kW, 25.0 kW,
250 kW, 2.50 MW, 250 MW
Accuracy: ±(4% +4 counts) |
Power Factor, PF
Displacement Power Factor, DPF |
Range: 0.00 to 0.25 Accuracy:
Not specified
Range: 0.25 to 1.0 Accuracy: ±0.04 |
| Harmonics
Display |
| Voltage |
Ranges: 1st to 51st harmonic
Accuracy: ±(3% +2 counts) to ±(15% +5 counts) |
| Current |
Ranges: 1st to 51st harmonic
Accuracy: ±(3% +8 counts) to ±(5% +8 counts) |
| Power |
Ranges: 1st to 51st harmonic
Accuracy: ±(5% +2 counts) to ±(30% +5 counts) |
| Line frequency |
Ranges: 40 Hz to 70 Hz fundamental
Accuracy: ±0.25 Hz |
| Phase |
Ranges: 2nd to 51st harmonic
Accuracy: ±3 ° to ±15 ° |
| K-factor |
Ranges: 1.0 to 30.0
Accuracy: ±10% |
| Sags and
Swells Recording |
| Recording times |
4 min to 16 days (selectable) |
| True-rms voltage |
Ranges: 5.000V, 50.00V, 500.0V,
1250V*
Accuracy: ±(2% +10 counts) |
| True-rms current |
Ranges: 50.00A, 500.0A, 5.000 kA,
50.00 kA
Accuracy: ±(2% +10 counts) |
| Other
Recording |
| Recording times |
4 min to 16 days (selectable) |
| Parameters |
| V/A/Hz |
Line voltage, current, frequency |
| Power |
Watts, VA, VAR, PF, DPF, frequency |
| Harmonics |
THD, harmonic voltage, (or current,
or power), frequency, % of total, phase |
| Ohms |
Ohms, diode, continuity,
capacitance |
| Temperature |
Temperature |
| Scope |
DC voltage, dc current, ac
voltage, ac current, frequency, pulse width, phase, duty cycle, peak max, peak min, peak
min-max, crest factor |
| Transient
Capture |
| Minimum pulse width |
40 ns |
| Voltage threshold settings |
20%, 50%, 100%, 200% above or below
normal voltage |
| Min voltage and max voltage at
cursor |
Ranges: 10V, 25V, 50V, 125V,
250V, 500V, 1250V
Accuracy: ±5% of full scale |
| Inrush Capture |
| Current ranges |
Ranges: 1A, 5A, 10A, 50A, 100A,
500A, 1000A |
| Inrush times |
Ranges: 1s, 5s, 10s, 50s, 100s, 5
min |
| Cursor readings, Current at
cursor |
Ranges: 12.5A, 25A, 50A, 125A,
250A, 500A, 1250A, 2500A, 5 kA
Accuracy: ±5% of full scale |
| Time between cursors |
Ranges: 4 to 235 pixels (1
pixel = inrush time/250)
Accuracy: ±(0.2% + 2 pixels) |
| Scope Display |
| Time ranges |
Ranges: 20 ns/div to 60 s/div |
| Max sampling rate |
Ranges: 25 MS/s |
| Bandwidth |
Voltage channel [1]: 20 MHz at inputs, 1 MHz
with TL24 Leads
Current channel [2]: 15 kHz at inputs, 10 kHz with 80i-500s Probe |
| Coupling |
AC, DC |
| Vertical sensitivity |
Ranges: 5 mV/div to 500V/div |
| Vertical resolution |
8 bit (256 levels) |
| Record length |
512 samples per channel |
| Timebase modes |
Normal, roll, single |
| Pre-trigger |
Up to 10 divisions |
| Measurements |
dc, ac, ac+dc, peak, peak-peak, frequency,
duty cycle, phase, pulse width, crest factor |
| Ohms, Diode,Continuity |
| Ohms |
Ranges: 500.0W, 5.000 kW, 50.00 kW, 500.0 kW,
5.000 MW, 30.00 MW
Accuracy: ±(0.6% +5 counts) |
| Diode voltage |
Accuracy: ±(2% +5 counts) |
| Continuity |
Beeper on at < (30W ±5W) |
| Max current |
0.5 mA |
| Capacitance |
Ranges: 50.00 nF, 500.0 nF, 5.000 µF, 50.00
µF, 500.0 µF
Accuracy: ±(2% +10 counts) |
| Temperature** |
Ranges: -100.0 °C to 400.0 °C, -200.0 °F to
800.0 °F
Accuracy: ±(0.5% +5 counts) |
| Screen Memories |
10 |
| Optically Isolated RS-232 Interface |
To printer:
Supports HP LaserJet, DeskJet, Epson FX/LQ and Postscript printers with optional PAC91
Printer Adapter Cable
To PC:
FlukeView Power Quality Analyzer Software included |
| FlukeView Power Quality
Software |
Hardware requirements:
PC or 100% compatible with Windows 3.1, Windows 95, or Windows NT. Enough RAM for Windows
operating system. 4 MB hard drive space. Pointing device (mouse) recommended. |
|
|
|
|

|
Thurlby Thandar
Instruments Ltd. Glebe Road, Huntingdon,
Cambridgeshire PE29 7DR U.K.
Tel: 01480 412451 Fax:
01480 450409 Email: sales@tti.co.uk Web:
http://www.tti.co.uk |
| |
|
|