Fluke 120 series Industrial ScopeMeter (model 123 and 124) from TTi in the UK
|
|
|
|
Fluke 120 Series Industrial ScopeMeters -
Specifications
|
|
|
|
|
The Fluke 120
Series Industrial
Scopemeter is a compact 20 MHz or 40MHz two channel scope and DMM. Ideal for troubleshooting
industrial machinery, instrumentation, control and power systems. The Fluke
120 series has unique features like Connect-And-View, and TrendPlot that simplify taking
measurements and reduce troubleshooting time when working in the field or in
industrial environments.
- 20 MHz or 40MHz, 25 MS/s
- Two Channels, Scope or
DMM mode
- 5 mV to 500 V/div
- 60 s to 20 ns/div
- NTSC, PAL, SECAM video
triggering
- True-RMS DMM with 5000
count / 0.5% accuracy
- 2 Channel TrendPlot for
recording trends and intermittents
- Optical RS-232 port for
connection to PC's
- Connect-And-View allows
for quick hands-off operation
|
|
|
| Dual
Input Oscilloscope |
| Vertical |
| Bandwidth |
20 MHz (model 123) or 40MHz (model 124) at inputs
With STL120 1:1 leads: 12.5 MHz
With PM 8918 10:1 probes (optional): Full Bandwidth |
| Coupling |
AC, DC |
| Sensitivity |
5 mV/div to 500 V/div |
| Vertical resolution |
8 bit |
| Accuracy |
± (2% of reading +0.05 x range/div) |
| Horizontal |
| Range |
20 ns/div to 60 s/div |
| Acquisition modes |
Normal, Single, Roll, Envelope, Smooth |
| Max. sample rate |
1.25 GS/s for repetitive signals
25 MS/s for single shot |
| Record length |
512 samples per channel |
| Accuracy |
± (0.1% of reading +0.04 x time/div) |
| Glitch capture |
40 ns or longer |
| Trigger |
| Source |
A or B. External via optional ITP120 |
| Modes |
Auto, Triggered, Single |
| Video |
NTSC, PAL, PAL+, SECAM
Random lines or User Selectable Line |
| Pre-trigger |
Up to 10 divisions of pre-trigger view |
| Measurements |
VDC, VAC, VAC+DC, Vpeak, Vpeak-peak, Frequency, Duty Cycle, Pulse Width and Phase.
Measurements can be scaled to Amps |
| Memory |
2 screens, 10 user setups |
| Dual
Input 5000 Count Autoranging Meter |
| DC Voltage VDC |
| Ranges |
500 mV, 5V, 50V, 500V, 1250V |
| Accuracy |
± (0.5% + 5 counts) |
| True RMS Voltage VAC and VAC+DC |
| Ranges |
500 mV, 5V, 50V, 500V, 1250V |
| Accuracy |
± (1% + 10 counts) |
| Additional Measurements and Functions |
Ohms, Continuity, Diode Test, Amps, °C or °F, Capacitance, dBV, dBm, Crest Factor,
Touch Hold and ZeroSet. (Amps, °C or °F with optional probes) |
| TrendPlot |
Graphs meter readings of the MIN and MAX values from 120 seconds to 16 days. Automatic
vertical scaling and time compression. Displays the actual and MIN, MAX or AVG reading. |
| General
Specifications |
| Display |
Cold cathode fluorescent backlit LCD. Contrast and
brightness user adjustable. Wide viewing angle. |
| Size |
72x72 mm (2.8x2.8 inch) |
| Power |
Line voltage adapter/battery charger included |
| Installed battery |
Rechargeable NiCd pack |
| Operating time |
Up to 5 hours |
| Charging time |
4 hours |
| Environmental |
| Temperature |
0°C to 50°C |
| Environmental |
MIL-T-28800E, Type III, Class 3, Style B |
| Electro-Magnetic Compatibility |
| Emission |
EN50081-1(1992): EN55022 and EN60555-2 |
| Immunity |
EN50082-2(1992):
IEC1000-4-2, -3, -5 |
| Enclosure protection: IP51,
IEC529 (dust, drip proof) |
| Mechanical Data |
| Size |
50x115x232 mm
(2x4.5x9.1 inches) |
| Weight |
1.2 kg (2.5 lb.) |
| Safety |
| Designed for measurements on 600V
Overvoltage Category III Installations, Pollution Degree 2, per:
|
ANSI/ISA S82.01-1994 EN61010.1 (1993)
(IEC1010-1) CAN/CSA-C22.2 No. 1010.1-92 UL3111-1 |
| Surge protection |
6 kV on input A and B |
Floating
measurements |
600 Vrms from any terminal to ground |
| Optically Isolated RS-232
Interface |
| To printer |
supports HP LaserJet®, DeskJet®,
Epson FX/LQ and Postscript |
| To PC |
dump and load settings and data, compatible with
FlukeView® Software SW90W/012E for Windows |
| Warranty |
3 years parts and labor |
|
|
|
|

|
Thurlby Thandar
Instruments Ltd. Glebe Road, Huntingdon,
Cambridgeshire PE29 7DR U.K.
Tel: 01480 412451 Fax:
01480 450409 Email: sales@tti.co.uk Web:
http://www.tti.co.uk |
| |
|
|