| XHR Common General Specifications (600W and 1000W) |
| Operational AC Input Voltage | 85-250 Vac, 47-63 Hz; Power factor corrected, 0.98 minimum for output load greater that 200 Watts. Connector IEC 320 15 A/250 V 600 W Models: 6.5 A max @ 100 Vac, 5.5 A max @ 120 Vac, 3 A max @230 Vac. 1000 W Models: 13 A max @ 100 Vac, 11 A max @ 120 Vac, 6 A max @230 Vac. Derate to 900 W @ less than 95 Vac |
| Time Delay | 3s maximum from power on until output stable |
| Voltage Mode Transient Response Time | 1 ms for output voltage to recover within 0.1% of previous level after step change in load current of up to 50% of rated output. |
| Maximum Voltage Differential | ±600VDC from output to safety ground |
| Remote Start/Stop and Interlock | TTL Compatible Input, selectable logic |
| Remote Analog Programming | Voltage: 0-5 k, 0-10 k resistances; 0-5 V, 0-10 V sources. Current: 0-5 k, 0-10 k resistances; 0-5 V, 0-10 V sources |
| Remote Analog Monitoring | 0 to full scale output 1% accuracy; Voltage: 0-5 V, 0-10 V monitor; Current: 0-5 V, 0-10 V monitor. |
| Operating Temperature Range | 0 to 50°C |
| Storage Temperature Range | -40 to 85°C |
| Humidity Range | 0 to 80% RH, non-condensing |
| Front Panel Voltage and Current Control | 10-turn voltage and current potentiometers |
| Front Panel Voltage Control Resolution | 0.02% of maximum voltage |
| AC Input Connector Type | 3-Terminal, 34A/250V, wire clamp connector with strain relief cover |
| Output Connectors | Nickel plated copper bus bars for models up to 40 V. Wire clamp connector for models over 40 V. Front Panel (when specified): 5-Way binding posts, 30 A max. |
| Size and Weight | 87.0 mm H x 214.6 mm W x 472.2 mm D; (3.425 in H x 8.45 in W x 18.59 in D) 8.2 kg (18 lbs) |
| Approvals | CE-marked units meet IEC 1010-1 safety standard, EN50081-2 and EN50082-1 EMC standards. Additional standards: CSA C22.2 No. 1010.1, UL 3101, and FCC, part 15, class A EMI standard |