California Instruments high performance, high reliability ac power sources
are available in the UK from TTid.
|
|
California Instruments TL series ac power supplies - available in the UK from TTid
|
|
|
| |

Description The TL
Series consists of two models, 251TL and 351TL, both using linear
technology. These units are ideal sources for special purpose AC power
applications that require variable voltage and frequency at high
frequencies and low noise and distortion levels. Both units provide
single-phase output. With simple knobs used to set voltage, frequency and
current limit, the TL Series provides an inexpensive source of low AC
power. All TL Series power source models can be used in table-top mode or
rack-mounted.
Download
Brochure/Data Sheet
Controller
Capabilities The TL Series uses a precision digital sine wave
generator to produce a low distortion output. Dual LCD readouts clearly
display programmed settings for voltage, current limit and frequency. Load
current is measured using true RMS sensing and can be displayed on the
front panel as well. Adjusting voltage, frequency and current limit is
accomplished using a set of digitally encoded rotary knobs. For ATE
applications, both IEEE-488 and RS232C interfaces are available as an
option.
Exclusive Features
- 45 Hz to 8000 Hz (Contact factory for requirements above 8 KHz)
- Dual voltage ranges
- Easy to Use
- Programmable
- Standard Current measurement
- Rack Mount
- Optional measurements for Peak Current, Voltage, Real Power, Apparent
Power, Power Factor and Crest Factor (with option -OP1)
- Rear panel Connections. (Front panel connections optional.)
- Optional IEEE-488 and RS232C interfaces
- CE Mark
Applications The
precise voltage regulation, low distortion and noise levels and wide
frequency range of the TL Series, combined with its easy to use front
panel, make it a great precision Lab AC source. Built in measurements may
be added (option -OP1) to extend the units usefulness for design
applications of AC powered products. Applications requiring high frequency
output such as gyro's, sensors and variable frequency controllers can be
tested and operated by a TL Series unit at up to 8000 Hz. Contact factory
for higher frequency requirements. The included PC control program
(requires -OP1 option) supports transient generation to simulate
real-world AC line conditions like brownouts, voltage sags, surges and
frequency fluctuations.
Output
Power The 351TL AC power source is rated for 350 VA with an output
voltage between 90 % and 100 % of range and a load power factor of 0.7 to
reflect typical operating conditions. Maximum RMS current is 2.8 A in the
135 V range. The 251TL is rated for 250 VA with an output voltage between
78 % and 100 % of range and a load power factor of 0.7. It's maximum
current is 2.0 A in the 135 V range.
Remote Control The optional
remote control interface allows complete control of all AC source
functions and provides measurement data to the controller. This allows the
TL Series AC sources to be used as a low cost AC test system. A Windows™
Graphical User Interface (GUI) program is included with the interface
option. Automatic power cycling and transient generation is made possible
with the use of this GUI program. The GUI output control, measurement and
transient screens are shown here. For quality assurance applications,
measured voltage, current and VA readings can be logged to disk for
documentation and analysis purposes. All data recorded is time stamped to
create a complete history of each test run. Up to eight often-used
front-panel setups can be stored in non-volatile memory for quick recall
from the PC controller through the interface. If needed, the front panel
can be locked out to prevent operator intervention during test
runs. The 251TL and 351TL offer additional features over the bus such
as the ability to select the turn-on or turn-off phase angle of the output
voltage. This capability, combined with the peak current measurement
function, enables inrush current analysis of a unit under test.
AC Transient
Generation Transient programming is
supported by the GUI program with user defined transient lists of up to
100 steps. Available transient functions are voltage step, voltage drop,
voltage sweep, voltage surge/sag, frequency step, frequency sweep,
frequency surge/sag as well as functions that combine both voltage and
frequency changes. The intuitive Windows™ interface greatly facilitates
creating and storing often used transient programs. Transient programs can
be recalled from disk and executed once, continuously or a specified
number of times. Editing functions such as delete and insert make it easy
to modify or expand existing programs. This capability makes it easy to
evaluate products for immunity to common AC line disturbances such as
brownouts, surges, swells, sags and frequency variations.
Available Models:
| 251TL |
250
VA programmable single phase AC source |
| 351TL |
350
VA programmable single phase AC source
| Factory Installed Options:
| -OP1 |
Option package 1.
Includes: |
|
- IEEE-488 and
RS232C remote control interface.
- Complete
measurements
- Function
Strobe output
- Remote
Inhibit input
- Windows™ GUI
program
- RS232C serial
cable.
|
| -RMS |
Rack-mount Slides. |
| -SKT |
Dual
universal front panel mounted output socket. |
| -L22 |
Locking knobs. Prevents changes to output settings from front
panel. |
Specifications:
-
| |
251TL |
351TL |
| Output
power |
|
250 VA |
350 VA
|
| No of output
phases |
|
1 |
1
|
| Voltage |
low
range |
0-135
Vrms |
| high
range |
0-270
Vrms |
| Accuracy |
± 0.1
% FS (45 - 100 Hz) ± 0.2 % FS (100 - 5000 Hz) ± 0.3 % FS (5000
- 8000 Hz) |
| Resolution |
0.1
V |
Load
regulation (remote sense) |
± 0.1
% FS |
| Line
regulation |
± 0.02
% FS |
| Distortion (into
resistive load) |
<
0.5 % (45 - 999 Hz) < 2.0 % (1000 - 8000 Hz) |
| Noise (full scale,
full power) |
-73
dB |
| Frequency |
Range |
45 -
8000 Hz |
| Accuracy |
± 0.02
% |
| Resolution |
0.01
Hz from 45.00 to 79.99 Hz 0.1 Hz from 80.0 to 799.9 Hz 1 Hz
from 800 to 8000 Hz |
| Max.
rms. current |
Low
range |
2.4
Arms |
2.8 Arms
|
| High
range |
1.2
Arms |
1.4 Arms
|
| Max.
peak current |
Low
range |
6.0 A |
6.0 A
|
| High
range |
3.0 A |
3.0 A
|
| Protection |
| Current
Limit |
Resolution |
0.1
Arms |
| Modes |
Const.
Voltage or Const. Current |
| Over
Temperature |
|
Ö |
| Over
Voltage |
|
Ö |
| Input |
| Voltage |
|
100,
115, 200, 230 ±10 % Vrms |
| Line
Current |
|
<
16 Arms |
| Frequency |
|
47 -
440 Hz |
| Hold up
time |
|
10
msec |
| Measurements |
Current (Standard) |
Range |
0.0 -
4.0 Arms |
| Accuracy |
0.2 %
FS + 0.3 % Rdng |
| Resolution |
0.001
Arms |
Peak
Current (option -OP1) |
Range |
0.00
-12.00 A |
| Accuracy |
0.5 %
FS + 0.5 % Rdng |
| Resolution |
0.01
A |
Voltage (option -OP1) |
Range |
0 -
300 Vrms |
| Accuracy |
0.1 %
FS + 0.05 % Rdng |
| Resolution |
0. 1
Vrms |
Power (option -OP1) |
Range |
800
W |
| Accuracy |
0.5 %
FS |
| Resolution |
0.2
W |
Apparent
Power (option -OP1) |
Range |
800
VA |
| Resolution |
0.2
VA |
Power
Factor (option -OP1) |
Range |
0.00 -
1.00 |
| Resolution |
0.01 |
| Interface |
| |
Option
-OP1 |
RS232C
and IEEE-488 |
| Regulatory |
|
CE
Mark |
| Mechanical |
| Dimensions |
HxWxD |
5.25 x
16.8 x 22 inches 133 x 427 x 560 |
| Weight
(lb./kg) |
|
70 lb.
/ 31 kg |
| Operating
Temp. |
|
0 -
40° C |
| Air intake /
exhaust |
|
rear /
sides |
See also: RP
Series for higher power switching AC power sources.
|
 |
|
|
|
|
|
|
|
Get More Information: ;
Please contact our sales desk and ask for the Ametek full-line
catalogue which contains full technical data on all of the models.
Alternatively a large amount of data is included on this site
including pdf data sheets, or use the Request Info button to ask for data
to be sent. |
|
Discuss an Application
or
Arrange a Demonstration:
Please contact our sales desk and ask to speak to one of our qualified
sales engineers.
They will be pleased to discuss the product and its use in your particular
application. They can also arrange a visit to demonstrate the
product. |
|
Place an Order
or get a Quotation:
Please use the Quote/Buy button or contact our sales desk for quotations and current availability
information.
|
|
|
|
|
|
|
 |
|
TTid.co.uk - Thurlby Thandar instrument distribution
Glebe Road, Huntingdon, Cambridgeshire PE29 7DR
Tel: 01480 412451 Fax: 01480
450409 Web: www.ttid.co.uk Email:
info@ttid.co.uk |
 |
| |
|