General Description The Ls Series is an improved version of the classic California
Instruments L Series AC power sources. It provides many basic AC source
capabilities at an economical cost. Additional capabilities such as
arbitrary waveform generation and harmonic measurements can be added as
options. The Ls Series can be ordered in either single phase (-1) or three
phase (-3) configurations. Power levels range from 3 kVA to 6 kVA in a
single chassis. Multiple chassis can be combined for power levels up to 18
kVA. The Ls Series is completely microprocessor controlled and can be
operated from a simple front panel keypad. A pair of analog controls
located next to the backlit alphanumeric LCD display allows output voltage
and frequency to be slewed up or down dynamically. For more advanced
operations, a series of menus is provided using a dual line high contrast
LCD display.
The Lx Series is a similar product with a built-in Power
Analyser and Arbitrary Waveform generator.
Download
Brochure/Data Sheet
Go
to Lx Series page
L Series
Backward Compatibility The Ls Series offers functional and bus compatibility with the CI L
Series AC power sources. Using the APE (Abbreviated Plain English) command
syntax, the Ls Series can be used in existing test systems without the
need to modify program code. The APE language is part of the -GPIB option,
which also adds the GPIB/ IEEE-488 interface.
Applications With precise output regulation and accuracy, high load
drive current, multi or single phase mode and built-in measurement
capabilities, Ls Series AC sources address many application areas for AC
power testing. Additional features, like available DO 160 or MIL 704 test
standards, make the Ls Series a good choice for avionics or defense
applications. All Ls Series AC sources are standard equipped with
RS232C remote control interfaces. An optional GPIB interface is available
as well.
Transient
Programming To simulate
common line disturbance occurrences, the Ls Series offers a list of
transient steps. These steps can be programmed from the front panel or
downloaded over the interface using the GUI program supplied. The GUI
allows libraries of commonly used line disturbances to be created on disk
for quick recall. Once downloaded, the transient program can be executed
from the PC or from the front panel. AC transient generation allows the
effect of rapid changes in voltage, frequency, phase angle and waveform
shape on the unit under test to be analyzed.
Measurements The following standard measurements are available from
the front panel or via the bus:
- Frequency
- Phase
- Voltage (rms)
- Current(rms)
- Peak Current
- Crest Factor
- Real Power
- Apparent Power
- Power Factor
Configuration Options The Ls Series is available in either three or one phase output
configurations and offers voltage ranges of 135 Vrms and 270 Vrms. A wide
range of options can be added to customize the Ls Series to meet your
specific application requirements.
Voltage Range Options (-HV
and -EHV) Output voltage range options are available to provide
higher voltage outputs. In addition to the standard 135/270 V range pair,
156/312 Vrms (-HV option) and 200/400 Vrms (-EHV option) can be specified
at the time of order. All voltage ranges are Line to Neutral. On three
phase Ls Series models, maximum Line to Line voltages are 467 V
(standard), 540 V (-HV option) and 692 V (-EHV option).
Phase
Mode (-MODE) The -MODE option provides automatic switching between
three phase and single phase output modes. In single phase mode, all
output current is routed to the Phase A output terminal. The -MODE option
is available for 3 phase Ls models (e.g. 4500Ls-3).
Waveform
Generation (-ADV option) The standard Ls Series provides sine wave
output capability. For more demanding test applications, the advanced
option package adds the following waveform capabilities:
- Squarewave.
- Clipped Sinewave - Simulates THD levels to test for harmonic
distortion susceptibility.
- Harmonic and Arbitrary (User defined) waveforms.
Using the
provided Windows Graphical User Interface (GUI) program, defining harmonic
waveforms is as easy as specifying the relative amplitude and phase angle
for each of up to 50 harmonics. The waveform data points are generated and
downloaded by the GUI to the AC source through the standard RS232C or
optional GPIB bus and are retained in non-volatile memory. Up to 50
waveforms can be stored and given a user defined name for easy recall.
Advanced Measurement Functions (-ADV option) Power
analysis of EUT load characteristics is available by adding the -ADV
option. Harmonics up to the 50th harmonic (for fundamental frequencies up
to 250 Hz) and total harmonic distortion of both voltage and current is
provided as well. Harmonic analysis data can be displayed on the front
panel display or on the PC using the GUI program. The GUI can also be used
to save and print harmonics data in tabular, bar graph or time domain
formats. The acquired voltage and current time-domain waveforms for each
output phase can be displayed using the GUI program. Waveform displays on
the PC. Available display modes include voltage and current combined,
three phase voltage, three phase current and true power. The time-domain
data is also available for transfer to a PC through the bus when using
custom software.
Windows
Graphical User Interface A Windows compatible Graphical User Interface (GUI) offers a soft
front panel interface for operation from a PC. The following functions are
available through this GUI program:
- Steady state output control (all parameters).
- Create, run, save and print transient programs.
- Measure and log standard measurements.
-
With -ADV
option:
- Generate and save harmonic waveforms.
- Generate and save arbitrary waveforms.
- Capture and display Voltage and Current waveforms.
- Measure, display, print and log harmonic voltage and current
measurements.
Output Power
|
Maximum power per phase: |
| Model: |
Single Phase |
Three Phase |
| 3000Lx |
3000
VA |
1000
VA |
| 4500Lx |
4500
VA |
1500
VA |
| 6000Lx |
5770
VA |
1923
VA | Power
Factor 0 to unity at full output
VA Voltage Ranges Low
: 0-135 Volt High
: 0-270 Volt Contact
factory for optional alternate voltage range pairs. Voltage
Resolution 100 mV Load
Regulation Less than ± 0.1%
FS Line Regulation Less than ±
0.02% for 10% line change Programming Accuracy
(25°C±5°C) Voltage
(rms): ±(0.1% + 0.3) V from 5.0 V to
FS. Frequency: ±
0.025% 45 Hz - 819.1 Hz ± 0.07% >
819.1
Hz
Phase: ±
1° 45- 100 Hz ±(1°
+ 1°/kHz) 100 Hz - 1 kHz Frequency
Range 45 Hz - 1000 Hz Max RMS
Current @ full power
| |
|
V
Range |
V
high |
V
low |
|
-3 |
3
Phs |
7.4
A |
14.8
A |
|
-1 |
1
Phs |
22.2
A |
44.4
A |
Note: Constant
power modes on 3000Ls and 4500Ls. Current available at reduced
voltage for 3000Ls, 4500Ls and max voltage for 6000Ls..
Max RMS Current @ FS Voltage
| |
|
V
Range |
V
high |
V
low |
|
3000Ls |
3 Phs 1
Phs |
3.7
A 11.1 A |
7.4
A 22.2 A |
|
4500Ls |
3 Phs 1
Phs |
5.5
A 16.7 A |
11.1
A 33.3 A |
|
6000Ls |
3 Phs 1
Phs |
7.4
A 22.2 A |
14.8
A 44.4 A |
Current
Limit Programmable from 0 A to max.
current for selected range. Peak Current
| |
3000Ls,
6000Ls: |
3.5 x Irms
at FS voltage. |
|
4500Ls: |
2.5 x Irms
at FS voltage. | Output Noise -100 mVrms
typical (20 kHz to 1 MHz) Harmonic
Distortion < 1% (At full scale
voltage, full resistive load.) Isolation
Voltage 300 V rms output to
chassis Output Relay Push
button controlled and bus controlled output
relay
|
Input Voltage
|
Models 3000Ls, 4500Ls, 9000Ls, 13500Ls: |
|
Standard: |
208-230 ±10%
VAC, (L-L, 3 Phase) |
| Option
-400: |
360-440 VAC,
(L-L, 3 Phase) |
| Models 6000Ls, 12000Ls, 18000Ls: |
|
Standard: |
208-230 +
10% VAC,(L-L, 3
Phase) | Notes: 1.
Input range must be specified when
ordering. 2 400 option not available on
6000Ls, 12000Ls or 18000Ls. Line Current (rms per
phase)
|
Model: |
187
VLL |
360
VLL |
| 3000Ls; |
19
A |
10
A |
| 3000Ls
(1ø); |
32
A |
n/a |
| 4500Ls; |
31
A |
16
A |
| 6000Ls
(@208V); |
38
A |
n/a |
Inrush Current
(per phase) @ 180-254
V 50 A
peak @
360-440 V 83
A peak Line Frequency 47 - 440
H Efficiency 75 %
typical Power Factor 0.6
typical Hold-up Time At least
10 ms
| Measurements
| Parameter |
Range |
Accuracy* (±) |
Resolution |
| |
|
1
ø mode |
3
ø mode |
|
| Frequency |
45.00
- 81.91 Hz 82.0 - 819.1 Hz > 819 Hz |
0.1% + 1 digit |
0.01
Hz 0.1 Hz 1 Hz |
| Phase |
45 -
100 Hz 100 - 1000 Hz |
0.5° 2° |
00.1° 1° |
| Voltage (AC) |
0 -300
V |
0.05% + 100mV |
10
mV |
| Current (AC rms) |
0 - 50
A |
0.1%
+ 150 mA |
0.1%
+ 50 mA |
1
mA |
| Real
Power |
0 - 5
kW |
0.15% + 9 W |
0.15% + 3 W |
1
W |
| Apparent Power |
0 - 5
kVA |
0.15% + 9 VA |
0.15% + 3 VA |
1
VA |
| Power
Factor |
0.00 -
1.00 |
0.03 |
0.01 |
0.01 | *
Accuracy specifications are in % of reading. Frequency measurement
accuracy applies for output voltages of 20Vrms and higher.
System Setup
storage 16 complete instrument
setups Transient lists
storage 100 transient steps per list
(SCPI mode) or 16 transient registers (APE mode).
Trigger
input Triggers measurements or
transient steps SMA connector: 10K
pull-up
Trigger output SMA
connector: HC TTL output.
Remote Control IEEE-488 Interface IEEE-488
(GPIB) talker
listener. Subset: AH1,
DC1, DT1, L3, RL2, SH1, SR1, T6 RS232C Interface
|
Bi-directional serial interface. |
| 9
pin D-shell connector |
| Handshake: |
CTS,
RTS |
| Data
bits: |
7 with
parity, |
|
8 without
parity |
| Stop
bits: |
2 |
| Baud
rate: |
9600 to
115200 |
| Supplied with RS232C
cable | Code and
Format SCPI APE
(option -GPIB)
|
Physical Dimensions (per
chassis) Height: 10.8"
(276
mm) Width: 16.96"
(431
mm) Depth: 23.7"
(602 mm) Depth includes rear panel
connectors and safety covers. All weights
and dimension are per chassis. Weight (per
chassis) 193 lbs / 87.7 Kg
net. 280 lbs / 127.3 Kg
shipping Vibration and
Shock Designed to meet NSTA project
1A transportation levels Air
Intake/Exhaust Forced air cooling,
side air intake, rear exhaust Operating
Temperature 0 to 35° C, full
power. Storage Temperature -40
to 85° C.
|
All specifications same as standard Ls models except
where noted.
-ADV
Option Waveforms Pre defined: Sine,
Square, Clipped User defined, 1024 addressable
data points. Storage: 50 user waveforms,
non-volatile memory.
Data
Acquisition Parameters: Voltage, Current
time domain, per phase. Resolution: 4096 data
points, 10.4 usec (1 phase) or 31.25 usec (3 phase) sampling
interval.
Measurements - Harmonics
| Parameter |
Range |
Accuracy* (±) |
Resolution |
| Frequency |
| Fundamental
| 45 - 250
Hz 0.09-12.5 kHz |
0.1% + 1
digit 0.5% + 1 digit |
0.01 Hz 0.1
Hz |
| Voltage |
Fundamental Harmonics 2 - 50 |
0.05% +
250mV 0.1%+0.1%/KHz+250mV |
10 mV 10
mV |
| Current |
Fundamental Harmonics 2 - 50 |
50 mA 0.1% + 50
mA +0.1% /1 kHz |
10 mA 10
mA | * Accuracy
specifications are in % of reading for single unit in 3 phase
mode.
-HV
Option Voltage Ranges
| |
Low
: |
0-135 Volt |
| |
High
: |
0-270
Volt | Max
RMS Current @ full power
| |
|
V
Range |
V
high |
V low |
| |
Mode: |
3
Phs |
6.4 A |
12.8 A |
| |
Mode: |
1
Phs |
19.2 A |
38.4
A | Note:
Constant power modes on 3000Ls and 4500Ls. Current available at reduced
voltage for 3000Ls, 4500Ls and max voltage for 6000Ls.
Max
RMS Current @ FS Voltage
| |
|
V
Range |
V
high |
V low |
| |
3000Ls |
3 Phs 1
Phs |
3.2 A 9.6
A |
6.4 A 19.2
A |
| |
4500Ls |
3 Phs 1
Phs |
4.8 A 14.4
A |
9.6 A 28.8
A |
| |
6000Ls |
3 Phs 1
Phs |
6.4 A 19.2
A |
12.8 A 38.4
A |
Frequency Range: With
-HF
option: 3000Ls, 4500Ls,
6000Ls: 45 Hz - 5000
Hz 9000Ls, 12500Ls, 13500Ls,
18000Ls: 45 Hz - 2000 Hz
-EHV Option All specifications same as standard Ls models except
where noted.
Voltage Ranges
| |
Low
: |
0-200 Volt |
| |
High
: |
0-400
Volt | Max
RMS Current @ full power
| |
|
V
Range |
V
high |
V low |
| |
Mode: |
3
Phs |
5.0 A |
10.0 A |
| |
Mode: |
1
Phs |
15.0 A |
30.0
A | Note:
Constant power modes on 3000Ls and 4500Ls. Current available at reduced
voltage for 3000Ls, 4500Ls and max voltage for 6000Ls.
Max
RMS Current @ FS Voltage
| |
|
V
Range |
V high |
V low |
| |
3000Ls |
3 Phs 1
Phs |
2.5 A 7.5
A |
5.0 A 15.0
A |
| |
4500Ls |
3 Phs 1
Phs |
3.8 A 11.3
A |
7.5 A 22.5
A |
| |
6000Ls |
3 Phs 1
Phs |
5.0 A 15.0
A |
10.0 A 30.0
A |
Frequency Range: With
-HF option:
45 Hz - 2000 Hz
-HF Option Frequency
Range: 3000Ls, 4500Ls,
6000Ls Standard, -HV: 45 Hz - 5000
Hz -EHV: 45 Hz - 2000
Hz All other
models: 45 Hz - 2000
Hz
Output Noise 250 mVrms typical
(20 kHz to 1 MHz)
Measurements F
< 2000 Hz: See standard Ls specifications. F
> 2000 Hz: See table.
| Parameter |
Range |
Accuracy* (±) |
Resolution |
|
|
1 ø mode |
3 ø mode |
|
| Frequency |
|
See
standard Ls |
1 Hz |
| Phase |
< 2000
Hz |
See
standard Ls |
|
|
> 2000
Hz |
5° |
1° |
| Voltage
(AC) |
0 -300 V |
0.2% +
100mV |
10 mV |
| Current (AC
rms) |
0 - 50 A |
0.5% + 150
mA |
0.5% + 50
mA |
1 mA |
| Real
Power |
0 - 5 kW |
0.5% + 9
W |
0.5% + 3
W |
1 W |
| Apparent
Power |
0 - 5
kVA |
0.5% + 9
VA |
0.5% + 3
VA |
1 VA |
| Power
Factor |
0.00 -
1.00 |
0.03 |
0.01 |
0.01 | *
See standard measurement specifications for notes.
| Model |
Output Power |
Phase Output |
Input Voltage11 |
| 3000Ls |
3 kVA |
1/3 |
208-230V ±10
% |
| 4500Ls |
4.5 kVA |
1/3 |
208-230V ±10 %
|
| 4500Ls-400 |
4.5 kVA |
1/3 |
400V
±10% |
| 6000Ls |
6 kVA |
1/3 |
208-230V ±10
% |
| 9000Ls |
9 kVA |
1/3 |
208-230V ±10 %
|
| 9000Ls-400 |
9 kVA |
1/3 |
400V
±10% |
| 12000Ls |
12 kVA |
1/3 |
208-230V ±10
% |
| 13500Ls |
13.5
kVA |
1/3 |
208-230V ±10 %
|
| 13500Ls-400 |
13.5
kVA |
1/3 |
400V
±10% |
| 18000Ls |
18 kVA |
1/3 |
208-230V ±10 %
| Note (1): All
input voltage specifications are for Line-to-Line three phase, delta or
wye. Model 3000Ls (208 V input) can be operated on 230 V L-N single-phase
if needed.
Options
| Input
Options
|
| -400 |
400 Volt
Line-to-Line AC input. [Not available on 6000Ls model or 12000Ls
and 18000Ls Systems] |
| Output Options
|
| -AX1 |
Auxiliary outputs,
26 VAC, 5 VAC. Limits upper frequency to 800 Hz. |
| -HV1 |
135/270 V output
range. |
| -EHV1 |
200/400 V output
range. |
| -HF1 |
Extends upper
frequency limit. See HF table. |
|
| HF Table |
| Models |
Max.
Freq. |
| 3000Ls,
4500Ls, 6000Ls |
5000
Hz |
| 9000Ls/2,
12000Ls/2, 13500Ls/2,
18000Ls/2 |
2000
Hz | |
| -LF1 |
Limits output
frequency to 500 Hz. |
| Note 1: See option matrix |
| Controller Options |
| -160 |
RTCA/DO-160D,
Change 2, EuroCAE-14D and Airbus test firmware [Section 16, AC
only] |
| -704 |
Mil-Std 704 Rev D
and E test firmware. [AC only] |
| -ADV |
Advanced feature
set. Adds arbitrary waveform generation and harmonic analysis of
voltage and current. |
| -GPIB |
GPIB interface and
APE programming language |
| -MB |
Multi-box. Adds
controller to auxiliary chassis of multi-chassis systems. |
| -MODE |
Adds phase mode
selections for -3 models. |
| -L22 |
Locking
Knobs |
| -LKM1 |
Clock and Lock
Master |
| -LKS1,2 |
Clock and Lock
Auxiliary |
| -LNS2 |
Line
Sync. |
| -EXS2 |
External
Sync. |
| Note
1: See option matrix |
| Note2 : -LKS, -LNS and -EXS are mutually exclusive and
with Ext Trig function. |
| Cabinet Options |
| -RMS |
Rack-mount slides.
Recommended for rack-mount applications. |
C prefix Cabinet System. Installed and pre-wired in 19” cabinet.
| C prefix |
Cabinet System.
Installed and pre-wired in 19”
cabinet. | Option
Matrix: Note that some options are mutually exclusive as indicated
in the table below. An ‘o’ means the options can be combined. An ‘x’ means
they cannot.
|
HF |
LF |
HV |
EHV |
LKM |
LKS |
EXS |
AX |
| HF |
- |
x |
o |
o |
x |
x |
x |
x |
| LF |
x |
- |
o |
o |
o |
o |
o |
o |
| HV |
o |
o |
- |
o |
o |
o |
o |
o |
| EHV |
x |
o |
x |
- |
o |
o |
o |
o |
| LKM |
x |
o |
o |
o |
- |
x |
o |
o |
| LKS |
x |
o |
o |
o |
x |
- |
x |
o |
| EXS |
o |
o |
o |
o |
o |
x |
- |
o |
| AX |
x |
o |
o |
o |
o |
o |
o |
- |
|
 |
|
|
|
|
|
|
|
Get More Information: ;
Please contact our sales desk and ask for the Ametek full-line
catalogue which contains full technical data on all of the models.
Alternatively a large amount of data is included on this site
including pdf data sheets, or use the Request Info button to ask for data
to be sent. |
|
Discuss an Application
or
Arrange a Demonstration:
Please contact our sales desk and ask to speak to one of our qualified
sales engineers.
They will be pleased to discuss the product and its use in your particular
application. They can also arrange a visit to demonstrate the
product. |
|
Place an Order
or get a Quotation:
Please use the Quote/Buy button or contact our sales desk for quotations and current availability
information.
|
|
|
|
|
|
|
 |
|
TTid.co.uk - Thurlby Thandar instrument distribution
Glebe Road, Huntingdon, Cambridgeshire PE29 7DR
Tel: 01480 412451 Fax: 01480
450409 Web: www.ttid.co.uk Email:
info@ttid.co.uk |
 |
| |
|