California Instruments high performance, high reliability ac power sources
are available in the UK from TTid.
|
|
California Instruments L series ac power sources - available in the UK from TTid
|
|
|
| |

 Model
6000L-3PT shown - 6 KVA
Download
Brochure/Data Sheet |
Description Now you can test any
product that operates from AC power with the most compact, versatile
power source in the test industry. The L-Series’ small size provides
more power per inch than most other AC supplies. Highly efficient,
these products dissipate less heat than previous generation systems
and allow up to an additional 10 % output power.
With a programmable controller, L-Series models provide the most
comprehensive set of programmable functions in the industry.
Automatic remote calibration and comprehensive self-tests simplify
maintainability.
All L Series units are completely self-contained. Control is through
an embedded oscillator, factory configured to your specific
requirements. Output parameters are controlled via the front panel
or the IEEE-488 bus. Bus programming, standard with -P,
-PT and HGA controllers, allows programming and measurement function
readback compatible with a number of other standards including VXI,
MXI and RS232 via recommended translators. To simplify programming,
the standard unit supports both Abbreviated Plain English
programming and an ATLAS-based control language.
For avionics applications, any 3-phase model can be configured with
26 V and 5 V auxiliary outputs. (AX option)
The L Series is ideal for applications where small size, low heat
dissipation and light weight are important. These include DC power
supply testing, production test, quality assurance verification,
engineering and ATE. |
Controller Capabilities The L Series uses a modular
plug-in controller approach that enables several controllers with
different feature levels to be selected. For simple manual operation, the
-M controller provides rotary knobs for setting voltage and frequency.
Both front panel and computer control is available using one of the -P or
-PT controller options. Units equipped with -P or -PT controller options
also offer built in measurement functions. The following controller
options are available for the L Series.
| Controller
type |
Frequency
range* |
Special
features
|
| -M |
45 Hz - 5000 Hz
or 45 Hz - 2000 Hz |
Manual
controls
|
| -P |
45 Hz - 5000
Hz |
± 0.05 % FS RMS
load regulation Transient generation
|
| -PT |
45 Hz - 550
Hz |
Fast settling
time, average response load regulation. Transient
generation
| |
* Frequency range
can be extended down to 17 Hz at reduced voltage. Models 6000L and up have
upper frequency range of 440 Hz when in single phase output configuration.
All programmable controllers offer output
measurement functions for voltage, rms current, power, power factor, phase
(three phase systems) and frequency. Three phase models can be used in
single phase mode by adding the -MODE option which allows automatic
switching between single and three phase modes from both the front panel
and the IEEE-488 bus. Programmable controllers also include a standard
IEEE-488 remote control interface and a Windows ™ Graphical User Interface
(GUI) for PC control.
Exclusive
Features · Single phase, three phase and split phase
configurations · Mode option allows switching between single and three
phase output · Output frequency range up to 5000 Hz. · Full output
VA with 0 to 1 power factor · High peak current capability with up to
9:1 crest factor · Panel height between 5.25" and 31.5" based on power
level · Efficiency 75% typical or better. Generates less heat and
consumes less power · Abbreviated Plain English (APE) programming
language support and free Windows ™ application software · Optional
MIL-STD704 and RTCA-DO160C test firmware
Applications The extended output frequency range of 17 Hz
to 5000 Hz (-P Controller only with certain models) makes the L Series
suitable for both commercial and avionics applications. Dual voltage
ranges provide maximum output current at any programmed voltage up to 400
Volt. (-EHV option, some options are mutually exclusive) The built in
measurement functions often eliminate the need for additional test
equipment. Due to the many configuration possibilities of the L Series
family of products, California Instruments is able to supply systems that
specifically meet your application requirements. The L Series offers many
options and configuration choices, some of which affect output ranges.
Contact factory for configuration information.
Remote Control
All L Series AC
sources shipped with a programmable controller (-P or -PT) include a
Windows ™ Graphical User Interface (GUI) program. The GUI supports all
functions and capabilities of the L Series controller used. · Control
all output parameters such as voltage, current limit, phase and
frequency. · Compile lists of transient programs on disk for quick
recall and execution · Measure and record key output parameters such as
volt rms, current, peak current, real power, and power factor. · Run
RTCA/DO160C (requires option -160) or MIL-STD 704D tests (requires option
-704) · Monitor remote control commands over the bus using the built in
command viewer window to quickly learn how to program the L Series
yourself.
Of course, drivers for popular programming environments
such as LabView ™ are available as well for custom software development.
If needed, the front panel can be locked out to prevent operator
intervention during test runs.
Available Models: Determine the output power level and
the number of phases (1 or 3) required for your application. The following
standard configurations are available. For custom configurations, contact
California Instruments directly.
| Configuration |
No of
units |
Power |
Output
phases |
Line input
|
| |
|
|
|
See Input
Voltage Chart
|
| 2001L |
1 |
2000
VA |
1
|
| 2750L* |
1 |
3000
VA |
1 or 3 |
| 4500L |
1 |
5000
VA |
1 or 3
|
| 6000L |
1 |
6000
VA |
1 or 3
|
| 9000L |
2 |
10000
VA |
1 or 3
|
| 12000L |
2 |
12000
VA |
1 or 3
|
| 13500L |
3 |
15000
VA |
1 or 3
|
| 18000L |
3 |
18000
VA |
1 or 3
| * Note: Model 2750L can
be operated from 187 V - 252 V single phase, with full output power.
Included with each L Series
system · User and Programming Manual for -P or -PT controller or
User Manual for -M controller · LSGUI User Manual (-P and -PT)
Factory Installed Amplifier
Options: One of the following options may
be specified at time of order:
| -EHV |
High voltage. Changes output transformer to 200 / 400 V rms
L-N. (45 Hz to 1000 Hz output frequency range only).
|
| -HV |
High voltage.
Changes output transformer to 156 / 312 V rms L-N.
|
| -LV |
Low voltage.
Changes output transformer to 67.5 / 135 V rms L-N. Especially
useful when 115 V L-L output is required.
| One or more of the
following options may be specified at time of order:
| 210960
|
Rack slides.
|
| -AX |
Provides separate
isolated 26 VAC regulated and 5 VAC unregulated outputs. The 26 V is
normally used for servo-synchro excitation, and the 5 V for lamp
power. Available on Models 2750L, 4500L, 6000L and 1503L
only.
|
|
26
Volt |
|
| Accuracy:
|
±2%.
|
| Current Capacity:
|
3 Arms.
|
| Frequency:
|
360/440 Hz.
|
| Regulation:
|
±0.05%
|
| 5
Volt |
|
| Accuracy:
|
±5%.
|
| Current Capacity:
|
5 Arms
|
| -LKM:
|
Clock/Lock Master Unit. Installs necessary hardware to adapt
to one slave unit.
|
| -LKS: |
Clock/Lock Slave
Unit. Installs necessary hardware to accept Clock/Lock inputs from
LKM unit. Only two slave units may be driven from a master
unit.
|
| -OR: |
Adds output relay
control to 751L - Standard on all other L-Series models.
|
| -UP |
Allows 2750L,
4500L, 9000L and 13500L systems to be powered from 342 V to 456 V
L-L 3 phase input. Note: this option reduces the maximum output
power by 10 %. Not available on 6000L, 12000L and 18000L
systems.
|
Factory
Installed -P and -PT controller Options:
| -160
|
RTCA/DO-160C test firmware.
|
| -555 |
Lowered output
impedance. (Not available on all models)
|
| -704 |
Mil Std 704D test
firmware.
|
| -MODE |
Allows switching
between single and three phase mode. Available for 4500L to 18000L
models only.
|
| -MT: |
Primarily for
military applications, where CIIL and full confidence test is
required. Not available on 751L.
|
| -OMNI-1-6
|
Impedance matching
network for IEC-1000-3-3 flicker tests. One phase, 6 Arms. For use
with 751L, 1501L and 2001L.
|
| -OMNI-1-18
|
Impedance matching
network for IEC-1000-3-3 flicker tests. One phase, 18 Arms. For use
with 2750L and 4500L, single phase.
|
| -OMNI-3-6
|
Impedance matching
network for IEC-1000-3-3 flicker tests. Three phase, 6 Arms per
phase. For use with 1503L, 2750L and 4500L, three phase.
|
| -OMNI-3-18
|
Impedance matching
network for IEC-1000-3-3 flicker tests. Three phase, 18 Arms per
phase. For use with high power, three phase configurations.
|
| -RPV: |
Allows amplitude
of any L-Series unit, when using a manual oscillator, to be
programmed with an external 0 -10 VDC input.
|
| -SQW: |
Allows square wave
capability with programmable controller. Not available on 2750L-1,
4500L-1, 6000L or any multi-box system.
| Specifications
Output 1
| Specification |
Standard
Programmable Type -P |
Transient
Programmable Type -PT |
Manual Control Type
-M
|
Voltage Ranges |
Standard 0 - 135 V
or 0 - 270 V. All voltages are L-N. Programmable range change
included. Program different amplitudes each phase. |
Standard 0 - 135 V
or 0 - 270 V. All voltages are L-N. Programmable range change
included. Program different amplitudes each phase. |
Variable POT
control from 0 to FS. Optional (-RPV) 0 to FS based on 0 - 10 VDC
input. Switchable range change included.
|
Voltage Accuracy |
TRMS
Sense: ±0.135 V from 5 V to 135 V ±0.54 V from 135 V to 270
V All at 25°C ±1°C (based on TRMS reading). |
±0.7% FS from 5%
FS to FS Constant line, load and temperature at 25°C
±1°C. |
Variable
control. (Analog meter indication)
|
Load Regulation |
TRMS sense: ±0.05%
FS, no load to full load. |
-0.5% FS: 45 Hz -
100 Hz -2.0% FS: 100 Hz - 550 Hz |
±0.05%: 45 Hz to 5
kHz
|
Line Regulation |
±0.02% FS for ±10%
line change |
±2% of full output
for a ±10% line change |
±0.02% of full
output for a ±10% line change
|
Stability (Amplitude) |
±0.015% FS over 24
hours at constant line, load and temperature. |
±0.25% FS over 24
hours at constant line, load and temperature. |
±0.015% FS over 24
hours at constant line, load and temperature.
|
| Default
Voltage |
0.0/5.0 volts
(field selectable) |
0 volts |
N/A
|
Frequency Range* |
2750L-1P, 4500L-1P
& all multi-box systems: 45 Hz to 2 kHz -3P &
751L/1501L/20010L: 45 Hz to 5 kHz 6000L-1P, 12000L-1P: 45 Hz to
440 Hz |
All models except
6000L and 12000L: 45 to 550 Hz 6000L, 12000L: 45 to 440
Hz |
2750L-1M, 4500-1M
& all multi-box systems: 45 Hz to 2 kHz -3M &
751L/1501L/20010L: 45 Hz to 5 kHz 6000L, 12000L: 45 Hz to 440
Hz
|
Frequency Resolution |
0.01 Hz: 45 Hz to
99.99 Hz 0.1 Hz: 100 Hz to 999.9 Hz 1 Hz: 1000 Hz to 5000
Hz |
0.01 Hz: 45 Hz to
99.99 Hz 0.1 Hz: 100 Hz to 550 Hz |
3 digit
resolution
|
Frequency Accuracy |
±0.001% of
programmed value |
±0.001% of
programmed value |
±0.005% of set
value
|
Default Frequency (Initial Value) |
Any (within
range) |
Any (within
range) |
Setting
|
| Ext. Sync
Input |
TTL
level |
TTL
level |
N/A
|
External Amplitude Modulation |
N/A |
0 to 5 V RMS
signal generates 0 to 11% amplitude modulation of output
voltage. 45 Hz to 5 kHz signal |
0 to 5 V RMS
signal generates 0 to 11% amplitude modulation of output
voltage.
|
Phase
Angle Programming |
Phases B and/or C
relative to Phase A: 0 to ±360.0° in 0.1° increments |
Phases B and/or C
relative to Phase A: 0 to ±360.0° in 0.1° increments |
N/A
|
Phase Accuracy |
±2° |
±2° |
±3°
|
Distortion (45
Hz - 550 Hz) |
N/A |
0 to 20% THD with
sine waveform and 1% resolution |
N/A
|
| Settling
Time |
16 mSec
no-load,from 5V to 2% of final value; 16 mSec, full-load,to 15%
of final value. |
0.5 mSec |
N/A
|
| Current
Limit |
Adjustable trip
Adjustable trip Adjustable hold-off |
Adjustable fold
back with recovery
|
| Remote
On/Off |
Contact closure
turn off |
Contact closure
trip off |
Contact closure
turn off
| * Lower limit is 17 Hz
with voltage restrictions Current
capability
| Model |
Total Power 35° C 1 |
Output (Phase) 2 |
Total Current Rating on 135 V RNG |
3
pH A rms/pH |
Size/Weight 6
|
| A
rms |
A peak
3 |
A peak
4
|
| 751L |
833 VA |
1 |
6.1 |
55.6 |
6015 |
n/a |
A
|
|
1501L |
1,667 VA |
1 |
12.3 |
55.6 |
6030 |
n/a |
A
|
|
1503L |
1,667 VA |
3 |
12.3 |
27.8 |
30 |
4.1 |
A
|
| 2001L |
2,000
VA |
1 |
14.8 |
55.6 |
60 |
n/a |
A
|
| 2750L |
3,000
VA |
1/3 |
22.2 |
83.3 |
90 |
7.4 |
B
|
| 4500L |
5,000
VA |
1/3 |
37 |
83.3 |
90 |
12.3 |
B
|
| 6000L |
6,000
VA |
1/3 |
44.4 |
157.4 |
170 |
14.8 |
B
|
| 9000L |
10,000
VA |
1/3 |
74 |
166.6 |
180 |
24.7 |
C
|
| 12000L |
12,000
VA |
1/3 |
90 |
314.8 |
340 |
30 |
C
|
| 13500L |
15,000 VA
5 |
1/3 |
111.2 |
250.0 |
270 |
37 |
D
|
| 18000L |
18,000 VA
5 |
1/3 |
133.2 |
472.0 |
510 |
44.4 |
D
|
Notes
| (1) |
Derate power by
10% for operation at 50° C ambient or when using with -UP
option.
|
| (2) |
1ø/3ø systems are
factory configured unless "MODE" option is specified.
|
| (3) |
Repetitive peak
current capability
|
| (4) |
Peak in-rush drive
capability (non-repetitive, less than 20 ms)
|
| (5) |
Similar products
available to 72,000 VA from the FCS Series. Contact factory for more
information.
|
| (6) |
See Dimensions,
weight and environmental Table below for specifications.
|
Input
| Voltage |
Input range must
be specified when ordering
|
| 751L, 1501L,
1503L, 2001L |
103 - 127 VAC,
L-N, Single phase or 207 - 251 VAC, L-N, Single phase
|
| 2750L, 4500L,
9000L, 13500L |
187 - 252 VAC,
L-L, Three phase (or 187 - 252 VAC, 1 Phase for 2750L
only)
|
| 6000L, 12000L,
18000L |
208 - 252 VAC,
L-L, Three phase
|
| 2750L, 4500L,
9000L, 13500L |
342 - 456 VAC,
L-L, Three phase with -UP option
|
| Line
Frequency |
47 - 440 Hz
|
| Hold up
time |
> 10
msec
|
Standard
Measurements, -P and -PT controllers
| Parameter |
Range |
Accuracy*
(±) |
Resolution*
|
| AC
Measurements
|
| Frequency |
16.00 - 99.99
Hz |
± 0.02
Hz |
0.01 Hz
|
| 100.0 - 500.0
Hz |
± 0.2
Hz |
0.1 Hz
|
| 500.0 - 999.9
Hz |
± 0.5
Hz |
0.1 Hz
|
| 1000 - 5000
Hz |
± 10
Hz |
1 Hz
|
| Phase |
0.0-360.0 |
± 2° |
0.1°
|
| RMS
Voltage |
0 -400
V |
1 V |
0.1 V
|
| RMS
Current |
0 - 40
A |
0.1 A |
0.01 A
|
| 0 - 400
A |
1 A |
0.1 A
|
| Real
Power |
0 - 2
kW |
10 W |
1 W
|
| >0 - 20
kW |
100 W |
10 W
|
| Apparent
Power |
0 - 2
kVA |
10 VA |
1 VA
|
| 0 - 20
kVA |
100 VA |
10 VA
|
| Power
Factor |
0.000 -
1.000 |
|
0.001
| * Measurement specifications shown are for -P or -PT controllers
only.
System
| Waveforms
|
| Waveform
Types |
Sine Square
(optional on -P and -PT) Clipped Sine, 0 - 20 % THD
|
| Transient Programming
|
| Transient Types
|
| Voltage: |
drop, step, sag,
surge, sweep
|
| Frequency: |
step, sag, surge,
sweep
|
| Voltage and
Frequency: |
step, sweep
|
| Transient register
Parameters: |
Voltage,
Frequency, Time, Slew rate, , Phase angle
|
| Transient
storage |
-P and -PT : up to
16 transient registers
|
| Time
resolution |
1 msec
|
| Time
range |
-P and -PT : 1
msec - 9999 sec
| Specification subject to change without notice.
Connectors
| Line
input |
Input terminal
block
|
| Output |
Output terminal
block
|
| Interfaces |
-P and -PT : 24
pin IEEE-488
|
| Remote
sense |
Remote voltage
sense terminal block
|
| Miscellaneous |
System
interface Clock and Lock BNC (2) (for rack enclosed system use
only)
|
Dimensions,
weight, environmental
|
A |
B |
C |
D
|
| Height |
5.25" / 133
mm |
10.5" / 267
mm |
21" / 533
mm |
31.5" 800
mm
|
| Width |
19" / 483
mm |
19" / 483
mm |
19" / 483
mm |
19" / 483
mm
|
| Depth |
23" / 584
mm |
23" / 584
mm |
23" / 584
mm |
23" / 584
mm
|
| Weight
(net) |
85 lbs / 39
Kg |
180 lbs / 82
Kg |
360 lbs / 164
Kg |
540 / 250
Kg
|
| Vibration and
Shock |
designed
to meet NSTA project 1A transportation levels
|
| Cooling |
Forced
air cooling, side air intake, rear exhaust.
|
| Operating
humidity |
0 to 95
% RH, non condensing
|
| Operating
Altitude |
0 - 6000
feet
|
| Operating
Temperature |
0 to 50
° Celsius
|
| Storage
Temperature |
-40 to +
85 ° Celsius
| Note: Dimension and
weight are for L Series chassis and controller exclusive of options. Multi
chassis configurations are shipped as individual units. |
 |
|
|
|
|
|
|
|
Get More Information: ;
Please contact our sales desk and ask for the Ametek full-line
catalogue which contains full technical data on all of the models.
Alternatively a large amount of data is included on this site
including pdf data sheets, or use the Request Info button to ask for data
to be sent. |
|
Discuss an Application
or
Arrange a Demonstration:
Please contact our sales desk and ask to speak to one of our qualified
sales engineers.
They will be pleased to discuss the product and its use in your particular
application. They can also arrange a visit to demonstrate the
product. |
|
Place an Order
or get a Quotation:
Please use the Quote/Buy button or contact our sales desk for quotations and current availability
information.
|
|
|
|
|
|
|
 |
|