California Instruments high performance, high reliability ac power sources
are available in the UK from TTi.
|
|
California Instruments i/iX series 11 ac power sources - available in the UK
from TTi
|
|
|
| |

Description The iX
Series offers a range of full featured, compact, high output AC and DC
power units that can be combined to provide up to 30 kVA of power in a
small amount of space. Offering 3 or 5 kVA per unit and a cabinet height
of only 7 inches, the iX Series represents the most compact AC/DC power
available today. The iX Series is a full featured source offering
transient generation, arbitrary waveform generation, standard
measurements, harmonic analysis, waveform acquisition and programmable
impedance.
Download
Brochure/Data Sheet
Controller
Capabilities The iX Series uses a sophisticated digital signal
processor based arbitrary waveform generator and power analyzer. This
integrated, multi instrument approach, effectively eliminates the need for
additional equipment to create an AC and DC power test system. Using a
large graphical LCD display, the advanced measurement and analysis
capabilities can be accessed directly from the front panel without the
need for remote control. For ATE applications, both IEEE-488 and RS232C
interfaces are included and Windows ™ Graphical User Interface application
software comes with each iX unit.
Flexible Configurations
Configuration
options include multiple unit single phase as well as multiple unit three
phase systems, for a power output level from 3 kVA to 30 kVA. Multi unit
systems can be field reconfigured to provide two or more smaller systems
or one high power system using the Multi Box option (option -MB). This
provides tremendous flexibility to meet different application requirements
by utilizing the same building blocks. Contact California Instruments for
details on the multi box option. The picture on the left shows a three
phase iX Series used as part of the CTS system.
The
following standard configurations are available:
| Configuration |
No. of
units |
AC Power |
Output phases DC Power
|
| 3001iX |
1 |
3000 VA |
2100 W
| 1
|
| 5001iX |
1 |
5000 VA |
3500 W
| 1
|
| 9003iX |
3 |
9000 VA |
6300 W
| 1 and 3
|
| 10001iX |
2 |
10000 VA |
7000 W
| 1
|
| 15001iX |
3 |
15000 VA |
10500 W
| 1
|
| 15003iX |
3 |
15000 VA |
10500 W
| 1 and 3
|
| 30003iX |
6 |
30000 VA |
21000 W
| 3 |
Exclusive Features
- Arbitrary
waveform generation
- Extensive
output transient generation
- Voltage,
Current and Power measurements
- Harmonic
analysis of Voltage and Current
- Waveform
acquisition of Voltage and Current
- Programmable
output impedance
- Drive
non-linear loads without derating
- Full output
power with 0 to 1 power factor
- Drive high
inrush current input stages
- High peak
current capability with up to 5:1 crest factor
- Panel height
only 7 inches
- Compact
design saves on rack space
- SCPI
programming language support and free application
software
- Closed Case
Calibration
- Optional MIL-STD704 (rev D and
E), 160RTCA/DO-160D,
IEC 1000-4-11 and IEC 1000-4-13 tests
Applications The extended output
frequency range of 16 Hz to 500 Hz make the iX Series suitable for
both commercial and avionics applications. Dual voltage ranges
provide maximum output current at any programmed voltage up to 300
Volt. The built in measurement and analysis functions eliminate the
need for additional test equipment. The low distortion output of
the iX Series and its programmable output impedance provide an
excellent platform for IEC Harmonics and Flicker testing. As such,
the iX Series is an integral part of the IEC Compliance Test System
(CTS).
Remote Control
All iX
Series AC/DC power systems include a Windows ™ Graphical User
Interface (GUI) program. The GUI supports all functions and
capabilities of the iX Series. The following tasks can easily be
performed through this graphical user interface using either the
IEEE-488 or RS232C interface:
- Define custom
waveforms by specifying their harmonic content
- Define custom
waveforms by free-hand drawing with the mouse
- Capture
output voltage and current waveforms
- Compile lists
of transient programs on disk for quick recall and
execution
- Run IEC
61000-4-11, IEC 61000-4-13 (requires option -413), IEC 61000-4-14,
IEC61000-4-17, IEC 61000-4-28 and IEC 61000-4-29 tests and print
test reports.
- Run
RTCA/DO-160D (requires option -160) or MIL-STD 704D and E tests
(requires option -704)
- Analyze
harmonic content of both voltage and current
- Compare
stationary harmonic voltage or current components against user
defined or pre-defined limits such as IEC 61000-3-2
Harmonics.
- Monitor
remote control commands over the bus using the built in command
viewer window to quickly learn how to program the iX series
yourself.
- Measure and
record key output parameters such as volt rms, current, peak
current, real power, and power factor.
Of course, drivers for
popular programming environments such as LabView ™ are available as
well for custom software development. If needed, the front panel can
be locked out to prevent operator intervention during test
runs.
Available Models: Determine the output power
level and the number of phases (1 or 3) required for your
application. Select the correct model number from the table
below.
|
-
| Model |
AC Power |
DC Power |
Output Phases |
Line Input
|
| 3001ix |
3000 VA |
2100 W |
1 |
208 VAC L-L, 1 Phase
|
| 5001ix |
5000 VA |
3500 W |
1 |
208 VAC L-L, 3 Phase
|
| 5001ix-400 |
5000 VA |
3500 W |
1 |
400 - 480 VAC L-L, 3
Phase
|
| 9003ix |
9000 VA |
6300 W |
1 or 3 |
208 VAC L-L, 1 Phase
|
| 10001ix |
10000 VA |
7000 W |
1 |
208 VAC L-L, 3 Phase
|
| 10001ix-400 |
10000 VA |
7000 W |
1 |
400 - 480 VAC L-L, 3
Phase
|
| 15001ix |
15000 VA |
10500 W |
1 |
208 VAC L-L, 3 Phase
|
| 15001ix-400 |
15000 VA |
10500 W |
1 |
400 - 480 VAC L-L, 3
Phase
|
| 15003ix |
15000 VA |
10500 W |
1 or 3 |
208 VAC L-L, 3 Phase
|
| 15003ix-400 |
15000 VA |
10500 W |
1 or 3 |
400 - 480 VAC L-L, 3
Phase
|
| 30003iX |
30000 VA |
21000 W |
3 |
208 VAC L-L, 3 Phase
|
| 30003iX-400 |
30000 VA |
21000 W |
3 |
400 - 480 VAC L-L, 3
Phase
|
Included with each iX
Series system
|
- User Manual
Programming Manual CIGUI Program and User Manual RS232C Serial Cable 9 pin to 9 pin
Rack mount handles
Factory Installed Options:
|
-160
|
RTCA/DO-160D test
firmware. (AC and DC tests)
|
| -411 |
IEC
61000-4-11 test firmware (see note).
|
| -413 |
IEC
61000-4-13 test firmware.
|
| -704 |
Mil Std 704E
test firmware. Supports rev D and E
|
| -MB |
Reconfiguration capability for Multi box power systems.
(See App Note
118)
|
| -EOS |
Electronic
Output Switch. Required to meet IEC 61000-4-11 AC Source
requirements. Single phase version.
|
| -EOS3 |
Electronic
Output Switch. Required to meet IEC 61000-4-11 AC Source
requirements. Three phase version.
|
| -LNS |
Line sync
option. Synchronizes output to input line frequency.
|
| -MODE-iX
|
Allows
switching between single and three phase mode. Available for
15003iX or 15003iX-400 models only.
|
| -OMNI |
Impedance
matching network for IEC-61000-3-3 flicker tests. May be used
in lieu of programmable impedance.
|
| -RMS |
Rackmount
Slides.
|
| -WHM |
Watt-Hour
measurements.
| Note: The -411 option allows IEC 61000-4-11 testing from the
front panel as well as over the bus and may be used in lieu of the
411 test sequence implemented in the GUI program. The GUI will
automatically use the -411 firmware option if its presence is
detected in the iX Series. If the -411 option is not installed, the
GUI will use a software implementation instead. In this case, a PC
is required to perform IEC 61000-4-11 testing.
| Output
|
| Modes |
AC, DC, AC+DC
|
| Frequency |
DC, 16 Hz - 500 Hz
|
| Load
regulation |
± 0.5% DC to 100
Hz ± 0.6% 100 Hz to 500 Hz in high voltage range ± 2.2% 100 Hz
to 500 Hz in low voltage range
|
| Line Regulation |
<± 0.1% for 10% line
change
|
Output
Noise (20 kHz to 1 MHz) |
<250 mVrms
typ. <500 mVrms max.
|
Harmonic
Distortion (linear load) |
Less than 1% from
16-66 Hz Less than 2% at 400 Hz
|
| DC Offset |
<20 mV
|
| External Modulation
depth |
0 - 10%
|
| Isolation Voltage |
300 Vrms output to
chassis
|
| Output
Relay |
Push button
controlled or bus controlled output relay
|
| Output
impedance |
Programmable Z on
3001ix, 5001ix, 9003ix and 15003ix
|
| . |
Voltage
Range |
RMS |
AC Peak |
DC Current |
| 3001iX |
135V |
22.2 |
110.0 |
15.6
|
| 150V |
20.0 |
14.0
|
| 270V |
11.1 |
96.0 |
7.8
|
| 300V |
10 |
7
|
| 5001iX |
135V |
37.0 |
110.0 |
26
|
| 150V |
33.3 |
23.2
|
| 270V |
18.5 |
96.0 |
13
|
| 300V |
16.7 |
11.6
|
9003iX with -mode-ix |
see
3001iX for three phase mode |
| 135V |
66.6 |
330.0 |
46.8
|
| 150V |
60.0 |
42
|
| 270V |
33.3 |
288.0 |
23.4
|
| 300V |
30.0 |
21
|
| 10001iX |
135V |
74.0 |
220.0 |
52
|
| 150V |
66.7 |
46.6
|
| 270V |
37.0 |
192.0 |
26
|
| 300V |
33.3 |
23.2
|
| 15001iX |
135V |
111.0 |
330.0 |
78
|
| 150V |
100.0 |
70
|
| 270V |
55.5 |
288.0 |
39
|
| 300V |
50.0 |
35
|
| 15003iX |
see 5001iX for
three phase mode |
see
15001iX for one phase mode Requires -Mode-iX
option |
| Voltage |
(Input range must be specified when ordering)
|
| 3001iX
only |
187 - 264 VAC,
L-N, Single phase
|
| Standard
models |
187 - 264 VAC,
L-L, Three phase
|
| All -400
models |
360 - 528 VAC,
L-L, Three phase
|
| Current per phase
|
| 3001iX |
30 Arms
|
| 9003iX |
30 Arms per unit
(3x)
|
| 5001iX /
-400 |
24 Arms / 12
Arms
|
| 10001iX /
-400 |
48 Arms / 24
Arms
|
| 15001iX and
15003iX / -400 |
72 Arms / 36
Arms
|
| Line
Frequency |
47 - 63 Hz
|
| Hold up
time |
>10 msec
|
| Parameter |
Range |
Accuracy* (±) |
Resolution*
|
| AC
Measurements
|
| Frequency |
16.00 - 500.0
Hz |
0.01%
+ 0.01 Hz |
0.01 Hz
|
|
|
<100
Hz |
100 - 500
Hz |
|
| RMS
Voltage |
0 - 330
V |
0.05 V +
0.02% |
0.1 V +
0.02% |
10 mV
|
| RMS
Current |
0 - 40
A |
0.05 A +
0.02% |
0.1 A +
0.02% |
1 mA
|
| Peak
Current |
0 - 120
A |
0.05 A +
0.02% |
0.1 A +
0.02% |
1 mA
|
| Crest
Factor |
0.00 -
6.00 |
0.05 |
0.05 |
0.01
|
| Real
Power |
0 - 6
kW |
10 W +
0.1% |
20 W +
0.1% |
1 W
|
| Apparent
Power |
0 - 6
kVA |
10 VA +
0.1% |
20 VA +
0.1% |
1 VA
|
| Power
Factor |
0.00 -
1.00 |
0.01 |
0.02 |
0.01
|
| DC
Measurements
|
| DC
Voltage |
0 - 300
V |
150
mV |
10 mV
|
| DC
Current |
0 - 40
A |
70
mA |
1 mA
|
| Power |
0 - 6
kW |
15
W |
1 W
|
*
Measurement system bandwidth = DC to 19.5 kHz. Accuracy
specifications are valid above 100 counts. Current and Power
Accuracy specifications are times two for 10001iX and times three
for 15001iX. For 10001iX and 15001iX, resolution decreases by factor
of 10, ranges for current and power increases by factor of three.
For units with -Mode-iX option, use 15001iX data for single phase
mode.
Harmonic
Measurements |
| Parameter |
Range |
Accuracy*
(±) |
Resolution
|
| Frequency
|
| Fundamental |
16.00 - 500.0
Hz |
0.01% + 0.01
Hz |
0.01 Hz
|
| Harmonics |
32.00 Hz - 19.5
kHz |
|
0.01 Hz
|
| Phase |
0.0 -
360.0° |
2° typ |
0.5°
|
| Voltage |
Fundamental |
250 mV |
10 mV
|
|
Harmonics 2 -
50 |
0.1% + 250 mV
+0.1% /1kHz |
10 mV
|
| Current |
Fundamental |
50 mA |
10 mA
|
|
Harmonics 2 -
50 |
0.1% + 50 mA
+0.1% /1kHz |
10 mV
|
*Accuracy specifications are valid above 100 counts. Accuracy
specifications are times three for three phase mode. Harmonics
frequency range in three phase mode is 32 Hz - 6.67 kHz. Resolution
decreases by factor of 10 for 10001iX and 15001iX. For units with
-Mode-iX option, use 15001iX data for single phase
mode.
System
|
| Non Volatile
Memory storage |
6 complete instrument setups 200 user defined waveforms
|
| Waveforms
|
| Waveform
types |
Sine Square Clipped Sine, 0 - 20% THD User
defined
|
| User defined
waveform storage |
Four groups of 50
user defined arbitrary waveforms of 1024 points for a total of
200. One group can be active at a time
|
| Transient Programming
|
| Transient
Types |
|
| Voltage: |
drop, step, sag,
surge, sweep
|
| Frequency: |
step, sag, surge,
sweep
|
| Voltage and
Frequency: |
step, sweep
|
| Transient List
Parameters: |
Voltage,
Frequency, Time or cycles, Slew rate, Waveform shape,
Phase angle, Repeat
|
| Transient lists
storage |
up to 32 transient
steps per list
|
| Time
resolution |
1 msec
|
| Time
range |
1 msec - 9999
sec
|
| Maximum slew
rate |
50 usec for 10% to
90% of full scale change into resistive load
|
| Waveform Acquisition
|
| Channels |
Voltage and
Current for each phase
|
| Memory
Depth |
4096
samples/channel
|
| Maximum Sample
Rate |
39.0625
Ks/s
|
| Triggering |
Auto, Phase,
Transient
|
| Trigger
Delay |
|
| Pre-trigger |
0 - 104 msec 1
phase 0 - 312 msec 3 phase
|
| Post-trigger |
0 - 1000
msec
|
Specifications subject to change without notice
Connectors |
| Line
input |
Input terminal block with cover
|
| Output |
Output terminal
block with cover
|
| Interfaces |
24 pin IEEE-488
and 9 pin RS232C
|
| Remote
sense |
Remote voltage
sense terminal block
|
| Miscellaneous |
System interface
(for rack enclosed system use only) Clock and Lock BNC (2) (for
rack enclosed system use only)
|
| Dimensions, weight,
environmental |
| Height |
7" / 178 mm
|
| Width |
19" / 483
mm
|
| Depth |
24" / 610
mm
|
| Weight |
61 lbs / 28 Kg
net 80 lbs / 36 Kg shipping
|
| Vibration and
Shock |
designed to meet
NSTA project 1A transportation levels
|
| Cooling |
Forced air
cooling, side air intake, rear exhaust.
|
| Operating
humidity |
0 to 95 % RH, non
condensing
|
| Operating
Temperature |
0 to 40 °
Celsius
|
| Storage
Temperature |
-40 to + 85 °
Celsius
|
Note:
Dimension and weight are for a single 3001iX or 5001iX chassis.
Multi chassis configurations are shipped as individual units.
See also: iM Series for manual
controller version or i Series for reduced
feature set programmable version. |
|
 |
|
|
|
|
|
|
|
Get More Information: ;
Please contact our sales desk and ask for the Ametek full-line
catalogue which contains full technical data on all of the models.
Alternatively a large amount of data is included on this site
including pdf data sheets, or use the Request Info button to ask for data
to be sent. |
|
Discuss an Application
or
Arrange a Demonstration:
Please contact our sales desk and ask to speak to one of our qualified
sales engineers.
They will be pleased to discuss the product and its use in your particular
application. They can also arrange a visit to demonstrate the
product. |
|
Place an Order
or get a Quotation:
Please use the Quote/Buy button or contact our sales desk for quotations and current availability
information.
|
|
|
|
|
|
|
 |
|
Thurlby Thandar Instruments
Limited
Glebe Road, Huntingdon, Cambridgeshire PE29 7DR
Tel: 01480 412451 Fax: 01480
450409 Web: www.tti.co.uk Email:
sales@tti.co.uk |
 |
| |
|