California Instruments high performance, high reliability ac power sources
are available in the UK from TTid.
|
|
California Instruments FX series ac voltage and current source - available in the UK from TTid
|
|
|
| |

General
Description With the combined voltage and current source in a
single compact chassis, the FX Series is the ideal choice for the simulation
of high power levels.
Either single or multi-phase, this versatile source can simulate power
levels from just a fewmilliwatts to 54kW single phase or 162 kW threephase
and provides a universal system for both manual and programmable control
applications.
Download
Brochure/Data Sheet
- Precision Voltage and Current Source
- 4500VA to 13500VA Output
- Single & Three Phase Configurations
- Computer Control for Automated Systems Remote programming and
collection of measurement data
- Separate Single Phase Outputs of up to 200A and 270V (L-N)
Simulation of power levels up to 54 KW
- Multiple Chassis Configurations for Two & Three Phase Systems Power
level simulation up to 162 KW for three phase operation
- Independent Full Capability Measurement System Monitors load
parameters without additional instrumentation
- Simulate True Power
- Great for Testing Watt-Hour Meters
Single Phase Systems
A single chassis includes a 1500 VA voltage source with 270V output
(optional 312V L-N) and a 200 A Current Source, which is derived from
exactly the same master oscillator as the voltage source. This means that
the voltage and current outputs are at precisely the same frequency,
although the phase relationship between the two may be varied to simulate
different load power factors.
Multi-Phase Systems
For either two or three phase systems, additional chassis are added. The
individual oscillators are clocked from a single master, with a phase lock
to ensure phase angle integrity. In multi-phase systems, the phase angle of
the voltage may be varied independently as well as the phase angle between
the voltage and current source for each phase.
The system can simulate two or three-phase outputs with a different P.F. on
each phase. This is extremely important when evaluating measurement or
control scenarios for multi-phase systems with unbalanced loads.
Wide Range Current Source
Whether the application is power simulation or just AC current, the FX
Series provides a very wide range of controllable constant current output
from 20 mA to 200 A. The current source section features three ranges to
ensure good resolution at low current settings. In fact, the 2 A range is
usable down to 20 mA. The 20 A to 200 A output is available via bus bar
outputs, whereas outputs below 20 A are available at the rear panel barrier
strip.
Fully Independent Measurement Capability
It is often difficult to provide accurate measurement capability at high
power levels. In addition to the basic accuracy of the source, the FX Series
provides a fully independent measurement system that may be used to verify
the output settings or determine the load characteristics.
This independent measurement system is included in each controller, which
means that independent and simultaneous monitoring of each phase is
possible. The parameter that is displayed on the front panel of the source
may be selected manually or by computer control. All measurement parameters
may be interrogated by a computer controller.
Full Programmability
The entire system, either single or multi-phase, is programmed from a
computer controller. The most popular control architecture is the IEEE-488
bus. However, other systems such as RS232C and VXI can be accommodated using
a simple protocol translator. All set up parameters, such as Voltage,
Current, Frequency and Phase Angle may be controlled. Additionally, in
multi-phase systems the relative angle between phases can also be changed
between 0° and 359°.
Measurement parameters may be selected and the result displayed on the front
panel, output to the computer, or a combination of both. Computer control is
particularly useful for the collection and tabulation of test results over a
series of different conditions such as temperature, load or frequency.
Graphical user interface programs are ideal for changing test requirements.
High Efficiency Design
The FX Series uses a pulse width modulated conversion technique which is
extremely efficient and allows the single phase system to be packaged in
just 10.5 inches of rack space at a weight of only 165 lb (75.2 kg).
Additional benefits are: a) that the unit uses less power than traditional
linear systems, and b) unit generates less heat.
Covers-on Calibration
Although periodic calibration is necessary for any precision system, down
time and interference with the production or engineering evaluation
operation can be disruptive. The FX Series however, allows routine
calibration to be performed either from the front panel or via the IEEE-488
bus. Disruption is minimized and full calibration can be achieved in
minutes.
|
 |
|
|
|
|
|
|
|
Get More Information: ;
Please contact our sales desk and ask for the Ametek full-line
catalogue which contains full technical data on all of the models.
Alternatively a large amount of data is included on this site
including pdf data sheets, or use the Request Info button to ask for data
to be sent. |
|
Discuss an Application
or
Arrange a Demonstration:
Please contact our sales desk and ask to speak to one of our qualified
sales engineers.
They will be pleased to discuss the product and its use in your particular
application. They can also arrange a visit to demonstrate the
product. |
|
Place an Order
or get a Quotation:
Please use the Quote/Buy button or contact our sales desk for quotations and current availability
information.
|
|
|
|
|
|
|
 |
|
TTid.co.uk - Thurlby Thandar instrument distribution
Glebe Road, Huntingdon, Cambridgeshire PE29 7DR
Tel: 01480 412451 Fax: 01480
450409 Web: www.ttid.co.uk Email:
info@ttid.co.uk |
 |
| |
|