California Instruments high performance, high reliability ac power sources
are available in the UK from TTid.
|
|
California Instruments EC1000S ac and dc power source - available in the UK from TTid
|
|
|
| |

Description The EC1000S is much more than an
AC/DC power source; it not only supplies AC and
DC power, it also can be used to perform dips, drops, surges, sags,
variations and other
abnormal power line conditions. In addition, the EC1000S will measure and
store standard power measurements and perform current harmonic analysis.
With its small footprint and weighing just 20 lbs, the EC1000S is suited for
both benchtop and field applications.
Download
Brochure/Data Sheet
Measurements
Built-in power measurement and analysis capabilities eliminate the need to
purchase
additional test equipment. All power output settings and measurements are
siultaneously
displayed on the large 5.7” LCD display.
Test Applications
The EC1000S is ideal for testing power supplies, modules, components, and
other non-linear loads.
Instrument Control Software
The EC1000S includes powerful and easy-touse Instrument Control Software
that makes
generating test sequences, and measurement power output paramaters, fast and
easy. The software can be used to quickly create user defined output
waveforms.
Key Features
- 750 VA - 1000 VA
Single phase output
- Bench-top Portability -
Compact and light (weighs 20 lbs)
Large LCD Display
- Large 5.7” LCD display makes it easy
to view settings and measurement values
Measurement Capabilities -
Measure output voltage, current, power, frequency, power
factor, crest factor, and harmonic current
- Measurement and Analysis Features
- Measures current harmonics and includes data log
measurement and the ability to create and edit arbitrary waveforms
- Programmable Output -
Variable output voltage, frequency and current limits
- Quick Connect -
USB interface and universal receptacle makes remote connections
fast and simple
- Sequencing -
Easily program and run a series of transient events
|
|
|
Maximum Output |
AC: 750 VA (115V Input), 1,000 VA
(208V/230V Input)
DC: 750 W (115V Input), 1,000 W
(208V/230V Input) |
|
Modes (8) |
AC-INT, AC-EXT, AC-ADD, AC-SYNC,
AC+DC-INT, AC+DC-EXT, AC+DC-ADD,
AC+DC-SYNC |
|
Voltages |
AC: 100V Range: 0.0V-135.0V; 200V
Range: 0.0V-270.0V
DC: 100V Range: ±190.0V; 200V Range:
±380.0V |
|
Maximum Current |
AC/DC: 100V Range: 10A; 200V Range:
5A
Maximum Peak: 100V Range: 40 Apk;
200V Range: 20 Apk |
|
Frequency Setting Range |
1.0 Hz-550.0 Hz (resolution 0.1 Hz);
Accuracy: ± 100ppm |
|
Phase (Output on) |
Setting Range: 0.0° to 359.9°
(Resolution: 0.1°) |
|
Voltage Waveform |
Sine-wave, Square-wave,
Arbitrary-wave (up to 16 types
can be saved) |
|
Voltage Distortion |
0.5% maximum (50Hz/60Hz) |
|
Load Regulation |
0.5% maximum (at output terminal
under no load and rated resistance
load) |
|
Line Regulation |
0.2% maximum (power input voltage:
100V/120V/230V, no load, rated
output) |
|
|
 |
|
|
|
Output Voltage / Current / Power |
V: DC Average value, effective
value, peak value;
C: RMS + peak value hold,
P: Active power, apparent power, &
reactive power |
|
Load Power Factor / Crest Factor |
Power Factor Range: 0.00-1.00;
Crest Factor Range: 0.00-50.00 |
|
Output - Harmonic Current |
Range: Up to 40th-order (AC internal
oscillation mode, fundamental wave:
50/60Hz) |
|
External Sync Frequency |
Range: 40-500 Hz (external
synchronization mode) |
|
|
 |
|
|
|
Voltage Range |
AC 115V - AC 230V ± 10% (253V max.)
50Hz/60Hz ± 2Hz (single phase) |
|
Power Consumption / Factor |
1.4 kVA max./0.95min (AC 115V),
0.9min (AC 230V) |
|
|
 |
|
 |
|
|
|
|
|
Interface |
USB |
|
Capabilities |
The EC1000S can be controlled remotely from
an external computer via a USB interface.
The accompanying software supports use of
the following functions: • Data analysis through remote interface • Sequence editing and execution • Arbitrary waveform editing and transfer • Data logger (by capturing measured values) • Worldwide power supply input is supported |
|
|
|
|
|
Description |
The EC1000S is used to test electrical
devices below 1kVA. This powerful, yet
portable instrument can be used for almost
any application requiring less than 1 kVA of
power with a current below 10A/40Apk. |
|
Common Applications |
Some examples of common applications are:
medical equipment (medical imaging / medical
monitors/EKG systems), communication devices
(telephones/cell phones/mobile computers),
computer devices (scanners / monitors /
printers / computer systems), automobile (
motors / electrical system/hybrid
technology), avionic testing (control
panels), appliances (microwaves / ovens /
washers / dryers), home electronics (
televisions / CD / DVD players / stereos),
portable electronics (MP3 players/palm
computers/satellite radios). |
|
|
|
Mechanical Specifications |
|
|
Dimensions |
H: 7” (176mm) W: 10“ (258mm) D: 17“ (440mm) |
|
Weight |
20 lbs (9.5kg) |
|
Operating Temperature |
0-40°C, 5-85% RH (absolute humidity must be
within 1-25g/m3, no condensation) |
|
|
 |
|
|
 |
|
|
|
|
|
|
|
Get More Information: ;
Please contact our sales desk and ask for the Ametek full-line
catalogue which contains full technical data on all of the models.
Alternatively a large amount of data is included on this site
including pdf data sheets, or use the Request Info button to ask for data
to be sent. |
|
Discuss an Application
or
Arrange a Demonstration:
Please contact our sales desk and ask to speak to one of our qualified
sales engineers.
They will be pleased to discuss the product and its use in your particular
application. They can also arrange a visit to demonstrate the
product. |
|
Place an Order
or get a Quotation:
Please use the Quote/Buy button or contact our sales desk for quotations and current availability
information.
|
|
|
|
|
|
|
 |
|
TTid.co.uk - Thurlby Thandar instrument distribution
Glebe Road, Huntingdon, Cambridgeshire PE29 7DR
Tel: 01480 412451 Fax: 01480
450409 Web: www.ttid.co.uk Email:
info@ttid.co.uk |
 |
| |
|