California Instruments high performance, high reliability ac power sources

are available in the UK from TTid.

California Instruments EC1000S ac and dc power source - available in the UK from TTid

 

Description
The EC1000S is much more than an AC/DC power source; it not only supplies AC and
DC power, it also can be used to perform dips, drops, surges, sags, variations and other
abnormal power line conditions. In addition, the EC1000S will measure and store standard power measurements and perform current harmonic analysis. With its small footprint and weighing just 20 lbs, the EC1000S is suited for both benchtop and field applications.


 
Download Brochure/Data Sheet 


Measurements
Built-in power measurement and analysis capabilities eliminate the need to purchase
additional test equipment. All power output settings and measurements are siultaneously
displayed on the large 5.7” LCD display.

Test Applications
The EC1000S is ideal for testing power supplies, modules, components, and other non-linear loads.

Instrument Control Software
The EC1000S includes powerful and easy-touse Instrument Control Software that makes
generating test sequences, and measurement power output paramaters, fast and easy. The software can be used to quickly create user defined output waveforms.
 

Key Features

  • 750 VA - 1000 VA Single phase output
  • Bench-top Portability - Compact and light (weighs 20 lbs)
    Large LCD Display - Large 5.7” LCD display makes it easy to view settings and measurement values
    Measurement Capabilities - Measure output voltage, current, power, frequency, power factor, crest factor, and harmonic current
  • Measurement and Analysis Features - Measures current harmonics and includes data log measurement and the ability to create and edit arbitrary waveforms
  • Programmable Output - Variable output voltage, frequency and current limits
  • Quick Connect - USB interface and universal receptacle makes remote connections fast and simple
  • Sequencing - Easily program and run a series of transient events

Output

Maximum Output AC: 750 VA (115V Input), 1,000 VA (208V/230V Input)
DC: 750 W (115V Input), 1,000 W (208V/230V Input)
Modes (8) AC-INT, AC-EXT, AC-ADD, AC-SYNC, AC+DC-INT, AC+DC-EXT, AC+DC-ADD, AC+DC-SYNC
Voltages AC: 100V Range: 0.0V-135.0V; 200V Range: 0.0V-270.0V
DC: 100V Range: ±190.0V; 200V Range: ±380.0V
Maximum Current AC/DC: 100V Range: 10A; 200V Range: 5A
Maximum Peak: 100V Range: 40 Apk; 200V Range: 20 Apk
Frequency Setting Range 1.0 Hz-550.0 Hz (resolution 0.1 Hz); Accuracy: ± 100ppm
Phase (Output on) Setting Range: 0.0° to 359.9° (Resolution: 0.1°)
Voltage Waveform Sine-wave, Square-wave, Arbitrary-wave (up to 16 types
can be saved)
Voltage Distortion 0.5% maximum (50Hz/60Hz)
Load Regulation 0.5% maximum (at output terminal under no load and rated resistance load)
Line Regulation 0.2% maximum (power input voltage: 100V/120V/230V, no load, rated output)

Measurements

Output Voltage / Current / Power V: DC Average value, effective value, peak value;
C: RMS + peak value hold,
P: Active power, apparent power, & reactive power
Load Power Factor / Crest Factor Power Factor Range: 0.00-1.00;
Crest Factor Range: 0.00-50.00
Output - Harmonic Current Range: Up to 40th-order (AC internal oscillation mode, fundamental wave: 50/60Hz)
External Sync Frequency Range: 40-500 Hz (external synchronization mode)

Input

Voltage Range AC 115V - AC 230V ± 10% (253V max.) 50Hz/60Hz ± 2Hz (single phase)
Power Consumption / Factor 1.4 kVA max./0.95min (AC 115V), 0.9min (AC 230V)
 

Remote Control

Interface USB
Capabilities The EC1000S can be controlled remotely from an external computer via a USB interface. The accompanying software supports use of the following functions:
• Data analysis through remote interface
• Sequence editing and execution
• Arbitrary waveform editing and transfer
• Data logger (by capturing measured values)
• Worldwide power supply input is supported

Applications

Description The EC1000S is used to test electrical devices below 1kVA. This powerful, yet portable instrument can be used for almost any application requiring less than 1 kVA of power with a current below 10A/40Apk.
Common Applications Some examples of common applications are: medical equipment (medical imaging / medical monitors/EKG systems), communication devices (telephones/cell phones/mobile computers), computer devices (scanners / monitors / printers / computer systems), automobile (  motors / electrical system/hybrid technology), avionic testing (control panels), appliances (microwaves / ovens / washers / dryers), home electronics ( televisions / CD / DVD players / stereos), portable electronics (MP3 players/palm computers/satellite radios).

Mechanical Specifications

Dimensions H: 7” (176mm) W: 10“ (258mm) D: 17“ (440mm)
Weight 20 lbs (9.5kg)
Operating Temperature 0-40°C, 5-85% RH (absolute humidity must be within 1-25g/m3, no condensation)
Get More Information: ;

Please contact our sales desk and ask for the Ametek full-line catalogue which contains full technical data on all of the models.
Alternatively a large amount of data is included on this site including pdf data sheets, or use the Request Info button to ask for data to be sent.
Discuss an Application or
Arrange a Demonstration:


Please contact our sales desk and ask to speak to one of our qualified sales engineers.
They will be pleased to discuss the product and its use in your particular application.  They can also arrange a  visit to demonstrate the product.
Place an Order
or get a Quotation:


Please use the Quote/Buy button or contact our sales desk for quotations and current availability information.

TTid.co.uk - Thurlby Thandar instrument distribution
Glebe Road, Huntingdon, Cambridgeshire PE29 7DR
Tel: 01480 412451  Fax: 01480 450409  Web: www.ttid.co.uk  Email: info@ttid.co.uk