California Instruments high performance, high reliability ac power sources
are available in the UK from TTid.
|
|
California Instruments CS series ac current source - available in the UK from TTid
|
|
|
| |

General
Description The CS Series represents an advanced AC current source
that addresses increasing demands on manufacturers to test products using
real-world current profiles. By combining true current transconductance
amplifiers with an advanced digital controller and harmonic power analyzer,
CS Series current sources are capable of performing tests that would
traditionally have been difficult to accomplish.
The CS Series is completely microprocessor controlled and can be operated
from a simple front panel keypad. An analog knob located next to the backlit
alphanumeric LCD display allows output current or frequency to be slewed up
or down dynamically. With precise current programming and regulation, high
output current, multi-phase mode and built-in power analyzer measurement
capabilities, CS Series AC current sources address many AC current test
applications. Additional features, like arbitrary waveform generation and
transient generation make the CS Series the ideal source for demanding
production test requirements.
All CS Series AC sources are equipped with IEEE-488 (GPIB), USB and RS232C
remote control interfaces and support SCPI command language programming. An
Ethernet interface is optional (-LAN Option).
Download
Brochure/Data Sheet
- Precision Current Source : Ideally suited for current protection
device testing
- Single and Three Phase Modes : Built-in phase mode switch makes
output configuration easy
- 3kVA to 18kVA Power Levels : Match power source & cost to
application requirements
- Arbitrary Waveform Generator : Test products using real world
current profiles including harmonic currents
- Built-In Power Analyzer : Performs voltage & current harmonic
analysis & waveform acquisition
- Standard IEEE-448, USB and RS232C : Remote control interface for ATE
system integration
- GUI Software Suite: Allows users to access the powerful features of
the instrument on a Windows™ system
- Programmable Transients : Amplitude & time control with up to 1ms
resolution
Current Control
The CS Series uses true current feedback control. This is considerably
different from many commonly available AC power sources that use a voltage
feedback scheme in combination with a constant current mode of operation.
Such power sources adjust the output voltage to try and maintain the
requested current level (Voltage controlled current). These voltage
controlled current sources have a finite response time to sudden impedance
changes, which typically results in dynamic current over or undershoot as
the load impedance changes. A current controlled current source does not
suffer from the response lag and will always maintain the current at the
specified level, regardless of transient load conditions. The maximum
compliance voltage supported by the CS Series is 135 Vrms. A lower
compliance voltage trip level can be programmed as needed.
Waveform Generation
The CS Series provides sine, clipped sine and square waveforms in addition
to user defined arbitrary waveforms. Harmonic waveforms can be used to test
for harmonic current susceptibility of a unit under test. With the help of
the supplied Windows Instrument Control Software (ICS), defining harmonic
waveforms is as easy as specifying the relative amplitude and phase angle
for each of up to 50 harmonics. The user also has the ability to define
arbitrary waveform data. Complex AC current anomalies can be simulated this
way. The waveform data points generated are downloaded by the ICS to the AC
source through IEEE-488, USB or RS232C bus. Up to 50 user-defined waveforms
can be stored and given a descriptive name for easy recall. Downloaded
waveforms are retained in non-volatile memory for recall over the bus or
from the front panel.
Transient Generation
To simulate complex current events, the CS Series offers a list of transient
steps. These steps can be programmed from the front panel or downloaded over
the interface using the software supplied. The ICS allows libraries of
commonly used sequences to be created on disk for quick recall. Once
downloaded, the transient program can be executed from the PC or from the
front panel. AC current transient generation allows the effect of rapid
changes in current, frequency and current waveform shape on the unit under
test to be analyzed. The combination of transients and user defined
arbitrary waveforms creates a powerful test platform for AC powered
products.
Measurements
The CS Series measurement system is based on real-time digitization of the
voltage and current waveforms using a 4K-sample buffer. The digitized
waveform data is processed by a Digital Signal Processor to extract
conventional load values such as rms voltage, rms current, real and apparent
power. The same data is also used to perform Fast Fourier Transformation (FFT)
to extract the harmonic amplitude and phase angle of 50 harmonics.
Standard Measurements
The following standard measurements are available from the front panel or
via the bus: Frequency, Phase, Voltage (rms), Current (rms), Peak Voltage,
Voltage Crest Factor, Real Power, Apparent Power, Power Factor
Advanced Measurement Functions
In addition to standard load parameters, the CS Series is capable of
measuring voltage and current amplitude and phase harmonics. Total harmonic
distortion of both voltage and current is also available. Advanced
measurement results like harmonic content of voltage and current for all
three phases are available over the bus. The ICS can be used to save and
print harmonics data in tabular, bar graph or time domain formats. The
acquired voltage and current time-domain waveforms for each output phase can
also be displayed using the software. Waveform displays on the PC include
voltage and current combined, three-phase voltage, three-phase current and
true power. The time-domain data is also available for transfer to a PC.
Windows Graphical User Interface
The Instrument Control Software (ICS) offers a soft front panel interface
for operation from a PC running Windows Vista™, Windows XP™, or Windows
2000™. The following functions are available through this software:
* Steady state output control (all parameters).
* Create, run, save and print transient programs.
* Generate and save harmonic waveforms.
* Generate and save arbitrary waveforms.
* Measure and log standard measurements.
* Capture and display Voltage and Current waveforms.
* Measure, display, print and log harmonic voltage and
current measurements.
|
 |
|
|
|
|
|
|
|
Get More Information: ;
Please contact our sales desk and ask for the Ametek full-line
catalogue which contains full technical data on all of the models.
Alternatively a large amount of data is included on this site
including pdf data sheets, or use the Request Info button to ask for data
to be sent. |
|
Discuss an Application
or
Arrange a Demonstration:
Please contact our sales desk and ask to speak to one of our qualified
sales engineers.
They will be pleased to discuss the product and its use in your particular
application. They can also arrange a visit to demonstrate the
product. |
|
Place an Order
or get a Quotation:
Please use the Quote/Buy button or contact our sales desk for quotations and current availability
information.
|
|
|
|
|
|
|
 |
|
TTid.co.uk - Thurlby Thandar instrument distribution
Glebe Road, Huntingdon, Cambridgeshire PE29 7DR
Tel: 01480 412451 Fax: 01480
450409 Web: www.ttid.co.uk Email:
info@ttid.co.uk |
 |
| |
|